1959
DOI: 10.1021/ac60156a030
|View full text |Cite
|
Sign up to set email alerts
|

Reactivity of Oxidizing Agents with Potassium Iodide Reagent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
6
0

Year Published

1964
1964
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 18 publications
1
6
0
Order By: Relevance
“…The concentration increased linearly with sonication time in the silica particle suspensions similar to the particle-free scenario ( Fig. 2 a–c), which is consistent with previous reports [17] , [36] . When φ p was low (0.05 vol%), slightly more I 3 − was detected at every point of time compared with the particle-free scenario; smaller particle diameters ( d p ) led to higher concentrations of I 3 − ( Fig.…”
Section: Resultssupporting
confidence: 92%
See 1 more Smart Citation
“…The concentration increased linearly with sonication time in the silica particle suspensions similar to the particle-free scenario ( Fig. 2 a–c), which is consistent with previous reports [17] , [36] . When φ p was low (0.05 vol%), slightly more I 3 − was detected at every point of time compared with the particle-free scenario; smaller particle diameters ( d p ) led to higher concentrations of I 3 − ( Fig.…”
Section: Resultssupporting
confidence: 92%
“…The pH value was initially adjusted to 8 ± 0.2 with KOH (0.1 M, purchased from Chengdu Jinshan Chemical Reagent Co., Ltd.). This is because I − in acidic solutions are susceptible to oxidation by oxygen gas, and I 3 − in strongly alkaline solutions is more likely to react with H 2 O 2 (formed by the recombination of ·OH) to form I − [36] , [37] . The silica particles were placed in the vessel, and KI solution was added to a height of 10.0 cm, prior to the sonochemical experiments.…”
Section: Methodsmentioning
confidence: 99%
“…Eriochrome Black T has been used for the determination of magnesium (4, 9, 22, 23, 32) and for the simultaneous determination of calcium and magnesium (32). A recently reported reagent for magnesium, Magon (1,16,17), is sensitive and forms a fairly stable complex with magnesium.…”
Section: Standardizingmentioning
confidence: 99%
“…Systematic ground-level O 3 monitoring began in the Los Angeles area in the 1950s. From 1959 to 1975, the California Air Resources Board (CARB) adopted a nonbuffered potassium iodide wet chemical method (Altshuller et al, 1959), which was found to have interferences from NO 2 and other trace oxidants such as peroxide, and PAN. As a consequence, the method was identified operationally as a total oxidant measure.…”
Section: Oxides Of Nitrogenmentioning
confidence: 99%