2016
DOI: 10.3390/s16122058
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell

Abstract: A breath analysis system based on ultraviolet-absorption spectroscopy was developed by using a hollow optical fiber as a gas cell for real-time monitoring of isoprene in breath. The hollow optical fiber functions as an ultra-small-volume gas cell with a long path. The measurement sensitivity of the system was evaluated by using nitric-oxide gas as a gas sample. The evaluation result showed that the developed system, using a laser-driven, high-intensity light source and a 3-m-long, aluminum-coated hollow optica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 29 publications
0
12
0
Order By: Relevance
“…Shao et al [137] discussed integration between the optical spectrometry and electrochemistry to sense NH 3 , without any calibration. Iwata et al [138] presented another sensor, using ultraviolet (UV) absorption spectroscopy with a calcium fluorite (CaF 2 ) window to analyze breath moisture in parts per billion levels.…”
Section: Opticmentioning
confidence: 99%
“…Shao et al [137] discussed integration between the optical spectrometry and electrochemistry to sense NH 3 , without any calibration. Iwata et al [138] presented another sensor, using ultraviolet (UV) absorption spectroscopy with a calcium fluorite (CaF 2 ) window to analyze breath moisture in parts per billion levels.…”
Section: Opticmentioning
confidence: 99%
“…The aluminum-coated fiber showed low losses compared to silver in the UV range of wavelengths. A transmission-loss spectrum of the aluminum HCW with an inner diameter of 1 mm for different length is shown in Figure 8b [58]. It can be observed from the figure that losses do not change linearly with the HCW length because there exist low-order modes and attenuation of high-order mode in long fibers.…”
Section: Optical Gas Cellmentioning
confidence: 99%
“…( a ) Optical losses for glass HCW with inner walls coated with aluminium (red), silver (yellow) and SiO 2 (green) [57]. ( b ) Optical losses of glass HCW coated with aluminum for different length of HCW [58]. …”
Section: Figurementioning
confidence: 99%
“…Additionally, most volatile gases show relatively large absorption in the UV region. Our group previously proposed a breath analysis method based on UV absorption spectroscopy using hollow optical fiber as a microvolume/long-optical path gas cell [ 20 , 21 ]. The proposed measurement system, composed of a laser-driven light source emitting a broadband spectrum in the UV region, a hollow optical fiber gas cell, and a fiber-coupled compact spectrometer, is both simple and cost effective.…”
Section: Introductionmentioning
confidence: 99%