IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society 2015
DOI: 10.1109/iecon.2015.7392825
|View full text |Cite
|
Sign up to set email alerts
|

Real-time coupling coefficient estimation and maximum efficiency control on dynamic wireless power transfer using secondary DC-DC converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…Based on a 3-coil WPT structure, dc-dc converters are used in [16] and [17] to alter and amplify the quality factor of the reflected impedance in order to maximize the overall energy efficiency. Since the optimal energy efficiency conditions change with the coupling coefficient k, a recursive least square filter is used to determine the instantaneous value of k and a buck converter is adopted after the diode rectifier in [18] to locate the maximum energy efficiency conditions. If space in the receiver module is not an issue, an auxiliary measurement coil has been added in the receiver side [19] to provide the phase information of the induced voltage so that the secondary control can tune the receive side and control the equivalent load resistance to the optimal value.…”
Section: A Using Dc-dc Converters For Altering Load Impedancementioning
confidence: 99%
“…Based on a 3-coil WPT structure, dc-dc converters are used in [16] and [17] to alter and amplify the quality factor of the reflected impedance in order to maximize the overall energy efficiency. Since the optimal energy efficiency conditions change with the coupling coefficient k, a recursive least square filter is used to determine the instantaneous value of k and a buck converter is adopted after the diode rectifier in [18] to locate the maximum energy efficiency conditions. If space in the receiver module is not an issue, an auxiliary measurement coil has been added in the receiver side [19] to provide the phase information of the induced voltage so that the secondary control can tune the receive side and control the equivalent load resistance to the optimal value.…”
Section: A Using Dc-dc Converters For Altering Load Impedancementioning
confidence: 99%
“…The fundamental resonant angular frequency is selected to be ωo. The input impedance of DWPT, Zin, is expressed in (14) and the output to input voltage gain can be derived result in (15). The plots of the gain curve for various loads and mutual inductances in The current of the primary coil can be obtained by applying Kirchhoff's law as shown in (10).…”
Section: Analysis and Characteristic Of Lcc-s Dwptmentioning
confidence: 99%
“…Some developments in DWPT have been published in the recent years. In [14,15] the authors focused on the control method of the DWPT and used the Series-Series (SS) compensation in their studies. The SS compensation has a simple topology, an independent load, and against frequency.…”
Section: Introductionmentioning
confidence: 99%
“…The results show a potential for significant improvement of the convergence speed. Kobayashi et al [6] explaining the efficiency is controlled by exchanging the input impedance at the receiving end of the converter. But the proposed method has not at all been useful in the sequence of coupling coefficient is desirable continually to attain the control.…”
Section: Literature Surveymentioning
confidence: 99%