2003
DOI: 10.1016/s0165-2370(02)00110-9
|View full text |Cite
|
Sign up to set email alerts
|

Real-time detection of PAH mixtures in the vapor phase at high temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…Firstly, the LIF spectra of PAHs highly depend on temperature. Although the spectroscopy of PAHs has been widely studied in solutions at room temperature [27][28][29], as well as in an optical cell at higher temperatures [30][31][32], the temperature effects on LIF signals of different PAHs are not well understood, and the spectrum data of PAHs at elevated temperatures are scarce. Secondly, PAHs formed in flames are multicomponent species with different and complex molecular structures, including different aromatic rings, five-membered ring structures, and aliphatic branched chains [33][34][35][36].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Firstly, the LIF spectra of PAHs highly depend on temperature. Although the spectroscopy of PAHs has been widely studied in solutions at room temperature [27][28][29], as well as in an optical cell at higher temperatures [30][31][32], the temperature effects on LIF signals of different PAHs are not well understood, and the spectrum data of PAHs at elevated temperatures are scarce. Secondly, PAHs formed in flames are multicomponent species with different and complex molecular structures, including different aromatic rings, five-membered ring structures, and aliphatic branched chains [33][34][35][36].…”
Section: Introductionmentioning
confidence: 99%
“…Allain et al [32] and R. Sun et al [37] had measured the LIF spectra of several PAH vapors and their mixtures at 300 ℃, and they both found that the spectra of mixtures can be calculated by linearly summing the spectra of each component. According to above discussion, the fundamental fluorescence characteristics and spectrum data of PAHs are essential to analyze the LIF spectra measured in flames, in order to obtain reliable quantitative data for the selected PAHs.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, fluorescence is used as a detection tool for PAHs in high-performance liquid chromatography and in laser-induced fluorescence (LIF) of vapor-phase PAHs at high temperatures. 37,38 LIF allows quantitative analysis of PAHs absorbed on quartz multichannel polydimethylsiloxane traps. 39 LIF coupled with fiber optics has also been employed in the determination of PAHs in cigarette smoke 29 and naphthalene has been determined in air.…”
Section: Introductionmentioning
confidence: 99%
“…Quantitative analysis of vapour phase PAHs at elevated temperatures by laser induced fluorescence (LIF) utilizing an excitation wavelength of 337.1 nm has been reported (Allain et al, 2003;Chi et al, 2001). Similarly, pyrene in cigarette smoke has been determined by LIF based on fiber optics with time resolution to enhance sensitivity (Song et al, 2003), although distortion of the fluorescence spectra in the fibres may occur (Kotzick and Niessner, 1996).…”
Section: Introductionmentioning
confidence: 99%