2014
DOI: 10.1109/tns.2014.2313574
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time, Fast Neutron Coincidence Assay of Plutonium With a 4-Channel Multiplexed Analyzer and Organic Scintillators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
19
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(19 citation statements)
references
References 10 publications
0
19
0
Order By: Relevance
“…However, classic fast neutron detectors often work at low energy range below several MeV, and most of the classic detector can hardly measure the energy, the direction, and the emission time of the original neutrons. So, new methods must be used to get above-mentioned information of neutrons [1][2][3][4][5][6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%
“…However, classic fast neutron detectors often work at low energy range below several MeV, and most of the classic detector can hardly measure the energy, the direction, and the emission time of the original neutrons. So, new methods must be used to get above-mentioned information of neutrons [1][2][3][4][5][6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%
“…The MFAx4.3 measures 350 mm × 260 mm × 110 mm and weighs 4.6 kg. Earlier renditions of the technology are reported [7], [8].…”
Section: Current Status Of the Technologymentioning
confidence: 99%
“…The controller includes an FPGA-based data acquisition card and custom-built analysis software developed in LabVIEW [7], [14]. 2) custommade de-randomizing electronics (Los Alamos National Laboratory, NM) connected to a JSR-15 multiplicity shift register (Canberra Industries Inc., CT) for the measurement of Uranium-235 enrichment in small samples of low-enriched triuranium octoxide [15], and 3) a bespoke 32-bit, 64-channel, binary counter with a serial PC interface (Lancaster University, UK) for reactor imaging [13] and neutron tomography using an isotropic source [16].…”
Section: A Review Of the Measurementsmentioning
confidence: 99%
“…ANY application systems adopt multiple organic scintillation detectors for fast neutron assay [1][2][3][4][5][6][7][8][9][10][11]. Detector arrays of this sort can consist of tens of detectors that rely on photo-multiplier tube (PMT) technology for scintillation light capture, voltage conversion and signal amplification.…”
Section: Introductionmentioning
confidence: 99%