Abstract:In this paper, the deformation fields of LY12 crack samples loaded by an SHTB are
real-time investigated with the time interval of 10 µs by an optical system, which consists of a
high-speed camera, a flash light, a frame grabber and a synchronization device with the delay-time
less than microsecond. The cracks are preset by using the three-points bending method in a MTS
fatigue machine. The crack is 2mm long with a flare angle of 60 degree. During the experiments,
the dynamic deformation images are captured by… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.