Real Time Ultrasound Elastography for the Differentiation of Benign and Malignant Thyroid Nodules

Abstract: The purpose of this study was to evaluate the predictive value of real-time ultrasound elastography (RUE) in differentiating benign from malignant thyroid nodules, with fine needle aspiration cytology analysis as the reference standard. A total of 78 consecutive patients with thyroid nodules who were selected for fine needle aspiration biopsies were examined in this prospective study. 78 nodules in these patients were examined by conventional ultrasound, and ultrasound elastography. The final diagnosis was obt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(1 citation statement)
references
References 39 publications
0
1
0
Order By: Relevance
“…The following devices using strain elastography: ElaXto (Esaote), RTE (Hitachi Aloka), elastography (General Electric, Philips, Toshiba, Ultrasonix), eSieTocuh: (Samsung, Siemens), respectively, ARFI: VirtualTouch Imaging: (Siemens) are currently present on the commercial ultrasound machine market [30]. It is worth mentioning that the amount of external applied pressure has to be medium and is quantified for each device: for Hitachi machines, the compression scale is displayed always, and the pressure should be between 3 and 4 [31,32]; in Siemens machines, it should be respectively a quality factor about 50 [33] and for Philips devices, it should maintain a steady pressure level displayed on the screen [34].…”
Section: Elastography Methods -Strain Elastographymentioning
confidence: 99%
“…The following devices using strain elastography: ElaXto (Esaote), RTE (Hitachi Aloka), elastography (General Electric, Philips, Toshiba, Ultrasonix), eSieTocuh: (Samsung, Siemens), respectively, ARFI: VirtualTouch Imaging: (Siemens) are currently present on the commercial ultrasound machine market [30]. It is worth mentioning that the amount of external applied pressure has to be medium and is quantified for each device: for Hitachi machines, the compression scale is displayed always, and the pressure should be between 3 and 4 [31,32]; in Siemens machines, it should be respectively a quality factor about 50 [33] and for Philips devices, it should maintain a steady pressure level displayed on the screen [34].…”
Section: Elastography Methods -Strain Elastographymentioning