2001
DOI: 10.1016/s0301-5629(00)00279-9
|View full text |Cite
|
Sign up to set email alerts
|

Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
183
0
3

Year Published

2004
2004
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 320 publications
(187 citation statements)
references
References 18 publications
1
183
0
3
Order By: Relevance
“…Thirdly, realtime therapy. For whole process of therapy, it is a real-time targeting and monitoring process, real-time estimating therapeutic effect and adjusting dosage [19] . Fourthly, suitable therapy.…”
Section: Discussionmentioning
confidence: 99%
“…Thirdly, realtime therapy. For whole process of therapy, it is a real-time targeting and monitoring process, real-time estimating therapeutic effect and adjusting dosage [19] . Fourthly, suitable therapy.…”
Section: Discussionmentioning
confidence: 99%
“…In conventional devices of focused ultrasound therapy, magnetic resonance imaging (MRI) and ultrasonic imaging have been used for treatment monitoring. 12,13) Since the lifetime of cavitation bubbles is on the order of 1 ms and up to the order of 10 ms even under sustained oscillation for maintaining the presence of bubbles, [14][15][16] the guidance by high-speed ultrasonic imaging achieving a frame rate of more than 1 kfps using unfocused transmission is promising. [17][18][19][20] Microbubbles such as cavitation bubbles are known to oscillate nonlinearly, and harmonic imaging is widely used for their detection.…”
Section: Introductionmentioning
confidence: 99%
“…We have been investigating ultrasound image-guided High Intensity Focused Ultrasound (HIFU) as a method for non-invasive hemorrhage control (Vaezy et al 2001a). HIFU therapy is capable of delivering cauterization energy deep inside the body, with millimeter accuracy, and with little or no damage to the intervening and surrounding tissues (Chen et al 1993;Vaezy et al 2001b).…”
Section: Introductionmentioning
confidence: 99%
“…Developing HIFU therapy into a non-invasive treatment modality requires precise localization and targeting of the injured sites, and monitoring of the HIFU treatment. Diagnostic ultrasound imaging (e.g., Power and Color Doppler) may be an efficient, real-time, and relatively cheap solution for both bleeding localization and HIFU treatment guidance (Vaezy et al 2001a). Although arteriography remains the gold standard, resent reports indicate the usefulness of ultrasound in localization of vascular injuries (Britt et al 2001;Davison and Polak 2004).…”
Section: Introductionmentioning
confidence: 99%