2020
DOI: 10.26782/jmcms.spl.6/2020.01.00014
|View full text |Cite
|
Sign up to set email alerts
|

Realization of Unity Power Factor for Ac/Dc Boundary Conduction Mode Flyback Converter With Any Specific Turn’s Ratio

Abstract: The boundary conduction mode (BCM) flyback converter is widely used topology because of numerous advantages like isolation between input and output circuits, minimum component count, low operating duct-cycle, and simple structure. However, it is not possible to achieve high input power factor (PF) as the on-time is constant. It causes the input current total harmonic distortion (THD) to not satisfy IEC61000-3-2 limits. For improving the PF of the BCM flyback converter, a variable on-time control (VOTC) method … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…In order to meet relevant harmonic standard and reducing input current distortion, various researchers have proposed different types of power factor correction (PFC) converters (García et al, 2003;Singh et al, 2011;Memon et al, 2016;Memon et al, 2018aMemon et al, , 2018bMemon et al, 2019aMemon et al, , 2019bMemon et al, , 2019cMemon et al, , 2019dMemon et al, 2020aMemon et al, , 2020bMemon et al, , 2020c.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to meet relevant harmonic standard and reducing input current distortion, various researchers have proposed different types of power factor correction (PFC) converters (García et al, 2003;Singh et al, 2011;Memon et al, 2016;Memon et al, 2018aMemon et al, , 2018bMemon et al, 2019aMemon et al, , 2019bMemon et al, , 2019cMemon et al, , 2019dMemon et al, 2020aMemon et al, , 2020bMemon et al, , 2020c.…”
Section: Introductionmentioning
confidence: 99%
“…So the industries have formed different standards like IEC61000-3-2 limit and IEEE 519. In order to meet relevant harmonic standard and reducing input current distortion, various researchers have proposed different types of power factor correction (PFC) converters (Memon et al, 2020a(Memon et al, , 2020b(Memon et al, , 2020c. The DC/DC converters or choppers such as buck, boost and buck-boost etc.…”
Section: Introductionmentioning
confidence: 99%
“…In order to meet relevant harmonic standard and reducing input current distortion, various researchers have proposed different types of power factor correction (PFC) converters (García et al, 2003;Singh et al, 2011;Memon et al, 2016;Memon et al, 2018aMemon et al, , 2018bMemon et al, 2019aMemon et al, , 2019bMemon et al, , 2019cMemon et al, , 2019dMemon et al, 2020aMemon et al, , 2020bMemon et al, , 2020c.…”
Section: Introductionmentioning
confidence: 99%