2001
DOI: 10.1007/s007760170020
|View full text |Cite
|
Sign up to set email alerts
|

Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
21
0
2

Year Published

2007
2007
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(23 citation statements)
references
References 26 publications
0
21
0
2
Order By: Relevance
“…Moreover, since the lesser trochanter is an attachment site for the psoas and flexor muscles, and gait disturbances resulted from abnormal hip flexion and dislocation caused by a decrease of soft tissue tension around the hip may occur if the lesser trochanteric fragment is not reduced. Several studies have addressed a variety of surgical techniques and instruments by paying attention to the importance of fixation of the greater and lesser trochanters272829). However, these instruments have led to unsatisfactory outcomes, and a study reported that complication rates were 30% for nonunion and 25.8% for irritation symptoms after using a grip plate28).…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, since the lesser trochanter is an attachment site for the psoas and flexor muscles, and gait disturbances resulted from abnormal hip flexion and dislocation caused by a decrease of soft tissue tension around the hip may occur if the lesser trochanteric fragment is not reduced. Several studies have addressed a variety of surgical techniques and instruments by paying attention to the importance of fixation of the greater and lesser trochanters272829). However, these instruments have led to unsatisfactory outcomes, and a study reported that complication rates were 30% for nonunion and 25.8% for irritation symptoms after using a grip plate28).…”
Section: Discussionmentioning
confidence: 99%
“…Fixation of a greater trochanteric fracture can be achieved using a standard wire or cable grip system. In the literature, the rate of nonunion for greater trochanteric fractures was reported to be 37.5% when using a standard wire or cable grip system [4]. The nonunion rate in the study described here was 18.7%.…”
Section: Discussionmentioning
confidence: 66%
“…Impaired function or dysfunction of the abductor lever arm may result in pain, tenderness, an increased risk of hip dislocation, a Trendelenburg gait pattern, and reduced quality of life [47]. …”
Section: Introductionmentioning
confidence: 99%
“…[22] 62 revizyon kalça artroplasti vakalarında yapmış olduğu trokanter major osteotomi sonrası kablo fiksasyonun medial kortekse dayandırılan grupta kaynamama oranının, medial kortekse drilleme yapılıp kablo uygulanan gruba göre yüksek olduğunu tespit ettiler. Bu nedenle kablo fiksasyonunda longitudinal mobilite önlemek için kablonun drill deliğinden geçilmesi gerekliliğini vurgulamışlardır.…”
Section: Discussionunclassified