2021
DOI: 10.1016/j.actbio.2021.04.050
|View full text |Cite
|
Sign up to set email alerts
|

Recent developments in next-generation occlusion devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 128 publications
0
13
0
1
Order By: Relevance
“…Once the defect is completely endothelialized and covered by newly formed autologous tissue, the task of the occluder is completed. Several studies have shown that 1-3 months are required for the fibrogranulation tissue to completely wrap around the interlay membrane, while endothelialization of the umbrella disc, particularly the raised section in the middle, requires 3-6 months (30,31). Therefore, the occluder need not be present 6 months beyond the procedure.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Once the defect is completely endothelialized and covered by newly formed autologous tissue, the task of the occluder is completed. Several studies have shown that 1-3 months are required for the fibrogranulation tissue to completely wrap around the interlay membrane, while endothelialization of the umbrella disc, particularly the raised section in the middle, requires 3-6 months (30,31). Therefore, the occluder need not be present 6 months beyond the procedure.…”
Section: Discussionmentioning
confidence: 99%
“…The umbrella disc material is derived from non-degradable stainless steel, cobalt alloy, and nickel-titanium alloy to degradable polylactic acid (PLA), PDO, polycaprolactone (PCL), etc. The material used for the interlayer membrane evolved from non-degradable PET, polytetrafluoroethylene (PTFE), and expanded PTFE (ePTFE) to biodegradable porcine intestinal collagen and PLA (31). Research and development of degradable occluders have been conducted worldwide for over 10 years, and more than 10-20 types of occluders have been developed successively.…”
Section: Discussionmentioning
confidence: 99%
“…A commercially available occluder (Shanghai Shape Memory Alloy Company, Shanghai, China) for the closure of ventricular septal defects (VSD) was selected as the basic design as shown in Figure 1 a, which consists of interlaced wires that slide and rotate as they deform. It is a self-expanding and self-centering occlusion device, prepared by weaving and thermoforming technology using 72 nitinol monofilaments with a diameter of 0.11 mm [ 13 ]. The most important part of the occluder device is the double-disc structure, the left and right circular discs, which are linked together by a short connecting waist, as shown in Figure 1 b [ 14 ].…”
Section: Methodsmentioning
confidence: 99%
“…Metode ROP lebih disukai karena menghasilkan polimer dengan nilai indeks polidispersitas (PDI) yang lebih rendah dan berat molekul yang lebih tinggi, serta sifat mekanik yang lebih baik. PCL biasanya disintesis tanpa katalis menggunakan polimerisasi pembukaan cincin, tetapi titik lelehnya yang rendah menghasilkan biaya produksi yang tinggi dan keterbatasan komersial [12][13]. Karena PCL digunakan terutama di bidang biomedis dan farmasi, maka harus diproduksi dengan hatihati untuk menghindari adanya senyawa toksik yang dapat menyebabkan efek samping pada pengguna atau organisme.…”
Section: Pendahuluanunclassified