DOI: 10.18174/498013
|View full text |Cite
|
Sign up to set email alerts
|

Receptomics, design of a microfluidic receptor screening technology

Abstract: Chapter 1 Introduction Chapter 2 A generic microfluidic biosensor of GPCR-activation-monitoring cytoplasmic Ca 2+ flux in human HEK293 cells Chapter 3 Metabolomics meets functional assays: coupling LC-MS and microfluidic cell-based receptor-ligand analyses Chapter 4 Calcium imaging of GPCR activation using arrays of reverse transfected HEK293 cells in a microfluidic system Chapter 5 The effect of calcium buffering and calcium sensor type on the sensitivity of an array-based bitter receptor screening assay Chap… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 244 publications
(388 reference statements)
0
1
0
Order By: Relevance
“…19 The slide or tongue-on-a-chip is then enclosed in a flow cell and connected to a microfluidic system, which ensures a constant flow of assay buffer across the receptor array and allows for sample loop injections into the existing flow, leading to precisely timed periods of ligand exposure (Figure 1). The strength of this specific tongue-on-achip application 20 is the similarity it holds to a human sensory experience of exposure windows to tastant solutions. It also facilitates the parallel assaying of an array of taste receptors versus a series of samples, each tested for a controlled period of time (typically 30−60 s) with ∼5 min intervals to allow sample wash-out and return of the cell calcium levels to baseline.…”
Section: ■ Introductionmentioning
confidence: 99%
“…19 The slide or tongue-on-a-chip is then enclosed in a flow cell and connected to a microfluidic system, which ensures a constant flow of assay buffer across the receptor array and allows for sample loop injections into the existing flow, leading to precisely timed periods of ligand exposure (Figure 1). The strength of this specific tongue-on-achip application 20 is the similarity it holds to a human sensory experience of exposure windows to tastant solutions. It also facilitates the parallel assaying of an array of taste receptors versus a series of samples, each tested for a controlled period of time (typically 30−60 s) with ∼5 min intervals to allow sample wash-out and return of the cell calcium levels to baseline.…”
Section: ■ Introductionmentioning
confidence: 99%