2020
DOI: 10.1088/1752-7163/ab8c50
|View full text |Cite
|
Sign up to set email alerts
|

Recognition of breathprints of lung cancer and chronic obstructive pulmonary disease using the Aeonose® electronic nose

Abstract: Objectives: There is a high unmet need in a non-invasive screening of lung cancer (LC). We conducted this single-center trial to evaluate the effectiveness of the electronic nose Aeonose® in LC recognition. Materials and Methods: Exhaled volatile organic compound (VOC) signatures were collected by Aeonose® in 42 incident and 78 prevalent LC patients, of them 29 LC patients in complete remission (LC CR), 33 healthy controls (HC) and 23 COPD patients. By dichotomous comparison of VOC’s between incident LC and HC… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(27 citation statements)
references
References 26 publications
0
26
0
1
Order By: Relevance
“…All studies were feasibility studies. The most commonly used e-noses were the Cyranose 320 (n = 12), 16 , 17 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 66 Aeonose (n = 11), 18 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 and PEN3 (n = 3). 41 , 42 , 43 Furthermore, a large heterogeneous group of custom-made e-noses were used (n = 26).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…All studies were feasibility studies. The most commonly used e-noses were the Cyranose 320 (n = 12), 16 , 17 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 66 Aeonose (n = 11), 18 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 and PEN3 (n = 3). 41 , 42 , 43 Furthermore, a large heterogeneous group of custom-made e-noses were used (n = 26).…”
Section: Resultsmentioning
confidence: 99%
“…A meta-analysis of all e-noses reporting diagnostic performance values was conducted on 46 studies, which included Aeonose (n = 11), 18 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 Cyranose 320 (n = 11), 16 , 17 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 PEN3 (n = 3), 41 , 42 , 43 and custom-made e-noses (n = 21). 6 , 8 , 9 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 Six studies 62 , 63 , 64 , 65 , 66 , 67 did not report diagnostic performance values and, therefore, could not be included in the meta-analysis.…”
Section: Methodsmentioning
confidence: 99%
“…It is noteworthy that commercial MOS-based chemiresistive e-Noses have been developed and studied for breath analysis and diagnosis. “Common Invent e-Nose”, for instance, has been used for asthma phenotyping and exacerbation prediction [ 90 ], while “SpiroNose” [ 91 ] and “ AeoNose® ” [ 92 ] have been used for asthma, COPD and LC patients and COPD, LC patients and HC differentiation, respectively. “DiagNose”, composed of 12 different doped MOS-sensors, comprises another promising example since it managed to differentiate 10 individuals through their breath samples [ 93 ].…”
Section: Types Of Nanomaterial-based Sensors In Breath Analysismentioning
confidence: 99%
“…Tausende dieser VOCs können im ausgeatmeten Atem gefunden werden. Künstliche Sensorsysteme, die meist aus einer Reihe von Sensoren für verschiedene Chemikalien bestehen, sind in der Lage, VOC-Muster in der ausgeatmeten Luft zu erkennen und verwenden dann erlernte Algorithmen zur Klassifizierung des «Atemabdrucks» und Vergleich mit zuvor aufgezeichneten Proben [1, 2].…”
Section: Transfer In Die Praxis Von Dr Fotios Drakopanagiotakis (Fuld...unclassified