1994
DOI: 10.1111/j.1740-8261.1994.tb01588.x
|View full text |Cite
|
Sign up to set email alerts
|

Recommendations for Standards in Transthoracic Two‐dimensional Echocardiography in the Dog and Cat*

Abstract: Recommendations are presented for standardized imaging planes and display conventions for two‐dimensional echocardiography in the dog and cat. Three transducer locations (“windows”) provide access to consistent imaging planes: the right parasternal location, the left caudal (apical) parasternal location, and the left cranial parasternal location. Recommendations for image display orientations are very similar to those for comparable human cardiac images, with the heart base or cranial aspect of the heart displ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
155
0
26

Year Published

2004
2004
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 167 publications
(184 citation statements)
references
References 4 publications
3
155
0
26
Order By: Relevance
“…Para a realização do modo bidimensional, seguiram-se as recomendações do Colégio Americano de Medicina Interna Veterinária e do Colégio de Cardiologia Veterinária (Thomas et al, 1993). Foram avaliadas as câmaras cardíacas e a contratilidade miocárdica.…”
Section: Methodsunclassified
“…Para a realização do modo bidimensional, seguiram-se as recomendações do Colégio Americano de Medicina Interna Veterinária e do Colégio de Cardiologia Veterinária (Thomas et al, 1993). Foram avaliadas as câmaras cardíacas e a contratilidade miocárdica.…”
Section: Methodsunclassified
“…Two-dimensional echocardiographical measurements were carried out using a 7-10 MHz phased array sector probe. LV end-diastolic diameter (LVEDD) was determined from parasternal projections [8]. Interstitial collagen volume fraction was determined with picrosirius red method from four different slices of Direct Red 80 (Fluka Chemika, Switzerland) stained left ventricular sections under polarized light.…”
Section: Methodsmentioning
confidence: 99%
“…Foram utilizados 40 cães adultos, não sedados, entre um, cinco e sete anos de idade, sendo 14 machos e 26 fêmeas (12 machos inteiros, dois machos castrados, 17 fêmeas castradas e nove fêmeas inteiras), com diferentes definições raciais e pesos corpóreos (de 3,2kg a 38,3kg (Thomas et al, 1993) e American Society of Echocardiography (ASE), com as adaptações sugeridas por Boon (1998) (Fig. 1).…”
Section: Methodsunclassified
“…Planos padronizados de imagem foram descritos para a ecocardiografia bidimensional em cães (Thomas et al,1993) com base no que já havia sido descrito na medicina humana. A avaliação da doença cardíaca esquerda, em geral, inclui a mensuração do tamanho do AE (Kienle e Thomas, 2002), que permite identificar a gravidade da doença cardíaca e o risco de se desenvolver insuficiência cardíaca congestiva esquerda (ICCE).…”
Section: Arq Bras Med Vet Zootec V64 N3 P585-592 2012unclassified