2017
DOI: 10.2514/1.b35406
|View full text |Cite
|
Sign up to set email alerts
|

Recommended Practice for Use of Inductive Magnetic Field Probes in Electric Propulsion Testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…This operating point corresponded to the highest total efficiencies from a recent performance study [23]. The pre-pulse neutral density is estimated to be in the n ≈ 1 × 10 19 range, and at its peak plasma density has been measured at n e ≈ 1× 10 19 1 m −3 with electron temperature peaking at T e ≈ 9 eV [13].…”
Section: Operating Conditionsmentioning
confidence: 82%
See 2 more Smart Citations
“…This operating point corresponded to the highest total efficiencies from a recent performance study [23]. The pre-pulse neutral density is estimated to be in the n ≈ 1 × 10 19 range, and at its peak plasma density has been measured at n e ≈ 1× 10 19 1 m −3 with electron temperature peaking at T e ≈ 9 eV [13].…”
Section: Operating Conditionsmentioning
confidence: 82%
“…The magnetic field measurements presented in this work were acquired using a two-axis Bdot probe constructed according to electric propulsion community best practices [19]. This probe consists of two orthogonally-oriented 1.25 cm diameter by 0.64 cm long fiberglass bobbins, around which 24 AWG enameled copper wire is wound.…”
Section: Inductive Probesmentioning
confidence: 99%
See 1 more Smart Citation
“…The first probe was located 0.5 cm from the drive coil face and 0.81 cm from the coil mid-plane. To calibrate output of the probes, a sensitivity curve was found for the range 100 kHz-500 kHz by using a pulsed Helmholtz coil in accordance with the procedure given by Polzin et al [21]. Integration of the Ḃr signals to obtain B r was achieved numerically using the same procedure for integrating data from the plasma Rogowski coil.…”
Section: Magnetic Field Measurementsmentioning
confidence: 99%
“…Inductive magnetic field probes, also called Ḃ probes, are routinely used in electric propulsion testing to measure unsteady magnetic field produced by time-varying currents [14,15,[43][44][45][46], and in laboratory magnetic confined plasma to detect magnetic field perturbation and MHD instabilities [10,47]. Operationally, these types of probes self-generate an output voltage when immersed in a time-changing magnetic field, proportional to dB/dt.…”
Section: Diagnosticsmentioning
confidence: 99%