1998
DOI: 10.1016/s0921-4534(98)00456-0
|View full text |Cite
|
Sign up to set email alerts
|

Reconstruction of critical current density profiles from AC loss measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

1999
1999
2002
2002

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(16 citation statements)
references
References 15 publications
0
16
0
Order By: Relevance
“…Measuring the parameters of forced oscillations of a PM one can obtain information about structure and electromagnetic properties of explored HTS samples. Figure 3 represents a basic system [24][25][26], which has been used with granular [27][28][29][30][31][32] and composite [30,32] YBCO and BSCCO ceramics, and, in a slight modification, with the meltprocessed YBCO quasi-single crystals [11,[32][33][34][35][36]. Here, the forced oscillations of the permanent magnet with mass m, magnetic moment , and diameter d, which levitates on the distance of x 0 over the surface of the HTS sample, have been induced by the AC coil, and their amplitude has been measured by the microscope with 5 m accuracy.…”
Section: Resonance Oscillation Techniquementioning
confidence: 99%
See 3 more Smart Citations
“…Measuring the parameters of forced oscillations of a PM one can obtain information about structure and electromagnetic properties of explored HTS samples. Figure 3 represents a basic system [24][25][26], which has been used with granular [27][28][29][30][31][32] and composite [30,32] YBCO and BSCCO ceramics, and, in a slight modification, with the meltprocessed YBCO quasi-single crystals [11,[32][33][34][35][36]. Here, the forced oscillations of the permanent magnet with mass m, magnetic moment , and diameter d, which levitates on the distance of x 0 over the surface of the HTS sample, have been induced by the AC coil, and their amplitude has been measured by the microscope with 5 m accuracy.…”
Section: Resonance Oscillation Techniquementioning
confidence: 99%
“…13, are observed for the samples just after manufacturing. With ageing of samples that firstly affects undersurface layers, these dependences become non-linear [36]. This means that the critical current density J c becomes spatially nonuniform.…”
Section: First Approximation: Energy Lossesmentioning
confidence: 99%
See 2 more Smart Citations
“…The basic system was used to investigate the granular [8][9][10][11][12][13][14] and composite [12] YBCO and BSCCO ceramics. To investigate the melt-textured YBCO samples the slight modification of it was used [15][16][17][18]. Scheme of such a basic system is represented in Fig.1.…”
Section: Resonance Oscillation Techniquementioning
confidence: 99%