2015
DOI: 10.1017/s0263034615000324
|View full text |Cite
|
Sign up to set email alerts
|

Reconstruction of electron beam energy spectra for vacuum and gas diodes

Abstract: In this paper, the spectra of electron beams produced in vacuum and gas diodes were analyzed to study the capabilities and limitations of their reconstruction from beam attenuation in foils of different thickness. The electron energy distributions were calculated using the Tikhonov regularization for Fredholm integral equations on minimum a priori assumptions. The spectra reconstructed in the study were those of electron beams, including a supershort avalanche electron beam, produced in experiments on a DUET p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
12
0
3

Year Published

2016
2016
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(16 citation statements)
references
References 31 publications
1
12
0
3
Order By: Relevance
“…Временное разрешение данного коллектора составляло ∼ 80 ps. При измерениях тока пучка полость коллектора откачивалась до остаточного давления ∼ 1 Pa. Распределение электронов по энергии определялось по ослаблению тока СЛЭП в фильтрах из алюминиевой фольги различной толщины методом, описанном в [26].…”
Section: экспериментальная установка и методики измеренияunclassified
“…Временное разрешение данного коллектора составляло ∼ 80 ps. При измерениях тока пучка полость коллектора откачивалась до остаточного давления ∼ 1 Pa. Распределение электронов по энергии определялось по ослаблению тока СЛЭП в фильтрах из алюминиевой фольги различной толщины методом, описанном в [26].…”
Section: экспериментальная установка и методики измеренияunclassified
“…In addition, the beam spends a few percent of the energy in gas heating when it passes the air gap of 2 cm between the foil and collector (Fig. 1), which also decreases the beam energy and greatly broadens its spectrum in the air (Kozyrev et al, 2015).…”
Section: Experimental and Theoretical Researchmentioning
confidence: 99%
“…Временное разрешение данно-го коллектора составляло ∼ 80 ps. Энергия электронов определялась по ослаблению тока СЛЭП в фильтрах из алюминиевой фольги различной толщины [15]. Для изменения амплитуды и плотности тока пучка и его длительности давление в газовом диоде, который за-полнялся гелием, варьировало от 3 до 760 Torr.…”
Section: экспериментальная аппаратура и методикаunclassified