2006
DOI: 10.1118/1.2161404
|View full text |Cite
|
Sign up to set email alerts
|

Reconstruction of electron spectra from depth doses with adaptive regularization

Abstract: Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned and this may lead to nonphysical oscillations in the reconstructed spectra. Use of a variational method of solution with a regularization technique removes the oscillations but tends to smooth the s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
7

Year Published

2008
2008
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 16 publications
0
9
0
7
Order By: Relevance
“…85 The energy distribution has been determined using spectral reconstruction algorithms, which find the spectrum that, when folded with monoenergetic depth dose curves, matches the measured depth dose curve. 48,65,86,87 This approach has been extended to determine multiple parameters of the beam model, including position of the virtual source. 88 The use of measurement-driven beam models obviates the need for beam simulation, and therefore circumvents the potential issues associated with the acquisition of detailed knowledge of the treatment head.…”
Section: C Measurement-driven Modelsmentioning
confidence: 99%
“…85 The energy distribution has been determined using spectral reconstruction algorithms, which find the spectrum that, when folded with monoenergetic depth dose curves, matches the measured depth dose curve. 48,65,86,87 This approach has been extended to determine multiple parameters of the beam model, including position of the virtual source. 88 The use of measurement-driven beam models obviates the need for beam simulation, and therefore circumvents the potential issues associated with the acquisition of detailed knowledge of the treatment head.…”
Section: C Measurement-driven Modelsmentioning
confidence: 99%
“…Este método de regularización tiene por objeto transformar la ecuación integral de primer tipo (mal definida) en la ecuación integral de segundo tipo, (bien definida) [20], pretendiendo amortiguar los errores contenidos en los datos de entrada [22] y así alcanzar una soluciónútil y estable.…”
Section: Dosis De Los Fotones De Frenadounclassified
“…This is due to the irregular electron spectra exiting the waveguide. Although the electron energy spectrum exiting the waveguide is often approximated as Gaussian, [14][15][16] in fact it can be highly asymmetric, 14,15 with a sharp decrease in electron population away from the nominal energy. An example of this can be seen in the work by Wei et al, 14 which gives electron spectra reconstructed from depth dose curves.…”
Section: Iib Beam Tuning To Maximize Currentmentioning
confidence: 99%
“…Although the electron energy spectrum exiting the waveguide is often approximated as Gaussian, [14][15][16] in fact it can be highly asymmetric, 14,15 with a sharp decrease in electron population away from the nominal energy. An example of this can be seen in the work by Wei et al, 14 which gives electron spectra reconstructed from depth dose curves. The results demonstrate that low-energy electrons, e.g., ranging from 1 to 3 MeV, are present in a 6 MeV spectrum; however, the relative fluence of these electrons is approximately one hundredth of that at the nominal energy.…”
Section: Iib Beam Tuning To Maximize Currentmentioning
confidence: 99%