Medical Imaging 2018: Ultrasonic Imaging and Tomography 2018
DOI: 10.1117/12.2293906
|View full text |Cite
|
Sign up to set email alerts
|

Reconstruction of ultrasound tomography for cancer detection using total least squares and conjugate gradient method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…the receivers adjacent to r = N r are r = {N r − 1, 1}.) Using ( 73), the two auxiliary rays used in (72) are replaced by two adjacent linked rays, which have already been calculated. (Note that ( 72) is used in this study.)…”
Section: Geometrical Spreadingmentioning
confidence: 99%
See 1 more Smart Citation
“…the receivers adjacent to r = N r are r = {N r − 1, 1}.) Using ( 73), the two auxiliary rays used in (72) are replaced by two adjacent linked rays, which have already been calculated. (Note that ( 72) is used in this study.)…”
Section: Geometrical Spreadingmentioning
confidence: 99%
“…For the latter, the amplitude on the second point along the ray was calculated using the analytical formula (20), and using an assumption that a neighborhood of each emission point with a radius larger than the ray spacing is acoustically homogeneous. The Jacobian on the rays' points was computed using (72), which required two auxiliary rays for each linked ray (emitter-receiver pair).…”
Section: Heterogeneous Mediummentioning
confidence: 99%
“…During ultrasound tomography, an array of transducers is used to collect information about the scattered field resulting from the excitation of an individual transducer to a region of interest. The process of exciting a unique transducer element while the rest of the array collects measurements is repeated until a predetermined number of elements have been excited [130]- [132]. To implement this in hardware, the collected data, usually on the order of several GBs, is transferred to a PC and then processed with custom reconstruction algorithms [133].…”
Section: Duration Of Tissue Heatingmentioning
confidence: 99%
“…Another method of determining these properties is the Distorted Born Iterative (DBI) method [130], [131], [136] which involves interactively solving the well-posed forward scattering problem followed by solving of the ill-posed inverse scattering problem to gain information about the total field within the ROI and the scattering function, respectively [131], [132]. This method relies upon the Born approximation, which becomes increasingly inaccurate when using high frequencies or imaging strongly scattering medium.…”
Section: Duration Of Tissue Heatingmentioning
confidence: 99%
See 1 more Smart Citation