2002
DOI: 10.1021/jf0258353
|View full text |Cite
|
Sign up to set email alerts
|

Recovery of Synthetic Pyrethroids in Water Samples during Storage and Extraction

Abstract: Monitoring for synthetic pyrethroids in surface water at the sub-parts per billion level requires reproducible sampling and analytical methods. We studied the recovery of bifenthrin, permethrin, and deltamethrin in water during storage in glass containers and extraction using solid-phase membranes. In solid-free water, the concentration of all compounds quickly decreased and then remained constant at 58-72% of the initial concentration, likely due to adsorption to the glass surface. The recovery was enhanced i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
53
0
2

Year Published

2007
2007
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 66 publications
(58 citation statements)
references
References 14 publications
3
53
0
2
Order By: Relevance
“…Surface water commonly differs from DI water in that the former contains certain amounts of suspended solids (Lee et al 2002). Since our facility is within walking distance to the American River, the method was validated using fortified American River water.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Surface water commonly differs from DI water in that the former contains certain amounts of suspended solids (Lee et al 2002). Since our facility is within walking distance to the American River, the method was validated using fortified American River water.…”
Section: Resultsmentioning
confidence: 99%
“…One study shows bifenthrin and permethrin degrade up to 41% within 3 days (Lee 2002). Sediment samples are collected in wide-mouth glass jars and must be frozen if not extracted within 14 days.…”
Section: Methodsmentioning
confidence: 99%
“…Dentre elas destacam-se a cromatografia gasosa (CG) acoplada a detector seletivo de captura de elétrons (DCE) 1,5,6 ou acoplada ao detector de massas no modo de seleção de íons [7][8][9] e a cromatografia líquida de alta eficiência (CLAE), acoplada a detector ultravioleta (UV) 10 . Atualmente são encontrados inúmeros trabalhos de monitoramento de resíduos de piretróides em águas 4,11,12 , solos [13][14][15] e alimentos 10,16,17 utilizando as mais diversas técnicas de extração e análise.…”
Section: Introductionunclassified
“…Dentre elas destacam-se a cromatografia gasosa (CG) acoplada a detector seletivo de captura de elétrons (DCE) 1,5,6 ou acoplada ao detector de massas no modo de seleção de íons 7-9 e a cromatografia líquida de alta eficiência (CLAE), acoplada a detector ultravioleta (UV) 10 . Atualmente são encontrados inúmeros trabalhos de monitoramento de resíduos de piretróides em águas 4,11,12 , solos [13][14][15] e alimentos 10,16,17 utilizando as mais diversas técnicas de extração e análise.Nos últimos anos, foram desenvolvidas técnicas de extração e purificação de resíduos de piretróides, com uma demanda menor de solventes, como a extração em fase sólida 11-13 e a microextração em fase sólida 4,18 . Apesar do desenvolvimento das técnicas de extração e microextração em fase sólida, a extração líquido-líquido continua sendo a mais empregada por ser uma técnica simples, que não exige instrumentação sofisticada, e de fácil execução.…”
unclassified
“…Synthetic pyrethroids (SPs), recognized as two different types by the absence (type I) or presence (type II) of an acyano group, are among the most commonly used insecticides [6]. The popularity of SPs is attributed to their high efficacy to insects, low environmental mobility, and relatively low mammalian and avian toxicity [7].…”
Section: Introductionmentioning
confidence: 99%