2017
DOI: 10.1016/j.jnucmat.2017.06.010
|View full text |Cite
|
Sign up to set email alerts
|

Reduced deuterium retention in simultaneously damaged and annealed tungsten

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
19
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 23 publications
2
19
0
Order By: Relevance
“…) − 𝐸 𝑑𝑖𝑓𝑓 𝑣𝑎𝑐 = 0.85 eV (6) This binding energy, according to equation ( 4) corresponds to a vacancy cluster of size n = 5.8. Of course sizes of vacancy clusters are integers, but this calculated size just means that the majority of cluster dissociation that explains our drop in small vacancy cluster annealing at 800 K should be mainly due to dissociation of cluster with sizes 6 and a smaller contribution by dissociation of clusters with 5 captured vacancies.…”
Section: Defect Type Iismall Vacancy Clustersmentioning
confidence: 99%
See 1 more Smart Citation
“…) − 𝐸 𝑑𝑖𝑓𝑓 𝑣𝑎𝑐 = 0.85 eV (6) This binding energy, according to equation ( 4) corresponds to a vacancy cluster of size n = 5.8. Of course sizes of vacancy clusters are integers, but this calculated size just means that the majority of cluster dissociation that explains our drop in small vacancy cluster annealing at 800 K should be mainly due to dissociation of cluster with sizes 6 and a smaller contribution by dissociation of clusters with 5 captured vacancies.…”
Section: Defect Type Iismall Vacancy Clustersmentioning
confidence: 99%
“…It is clear that in order to fully understand the influence of displacement damage on HI retention, one must understand the evolution of defects at elevated temperatures. In the recent past, several studies were conducted to address this in detail [4][5][6]. However, in all these cases the annealing of displacement damage in hydrogen-free tungsten was studied.…”
mentioning
confidence: 99%
“…However, as HD contributed only an average of 28% to the total D flux this is of minor importance. As described previously [17], variable ambient laboratory humidity, temperature, and length of vacuum break influence the water content adsorbed to the TDS chamber walls. This leads to a significant H 2 background signal that was scaled to and subtracted from the raw HD and D 2 signals.…”
Section: Final Tdsmentioning
confidence: 95%
“…Contaminants from polishing were removed in successive ultrasonic baths of acetone followed by ethanol. Next, the samples were annealed at 1173 K for 1 hour in a vacuum chamber below 10 −4 Pa. As noted in [17], a broken W sample displayed elongated grains perpendicular to the surface with dimension on the order of 10 µm parallel to the surface, as viewed by a scanning electron microscope. The maximum annealing temperature is well below the recrystallization temperature, leaving an intrinsic level of various defects throughout the bulk of the sample.…”
Section: Sample Preparationmentioning
confidence: 96%
See 1 more Smart Citation