2019 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) 2019
DOI: 10.1109/fleps.2019.8792267
|View full text |Cite
|
Sign up to set email alerts
|

Reduced graphene oxide decorated with metals nanoparticles electrode as electrochemical sensor for dopamine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 11 publications
1
3
0
Order By: Relevance
“…Figure 2A shows the deposition curve of rGO on the ITO-PET surface. As observed in previous works [75,76], a steady-state current density (−150 µA cm −2 ) is achieved after 100 s. The as-obtained substrate was then covered with PANI by electrochemical polymerization (Figure S2). At the beginning of the deposition, the growth curves show a different trend as the electrode/solution interface is different.…”
Section: Electrode Fabrication and Characterizationsupporting
confidence: 79%
“…Figure 2A shows the deposition curve of rGO on the ITO-PET surface. As observed in previous works [75,76], a steady-state current density (−150 µA cm −2 ) is achieved after 100 s. The as-obtained substrate was then covered with PANI by electrochemical polymerization (Figure S2). At the beginning of the deposition, the growth curves show a different trend as the electrode/solution interface is different.…”
Section: Electrode Fabrication and Characterizationsupporting
confidence: 79%
“…In order to increase the immobilization of the primary antibody, rGO was deposited on top of the ZnO NRs optimized electrodes using electrodeposition by applying a constant potential [115]. GO stock solution (4 mg/mL) was dispersed in acetate buffer solution with a final concentration of 0.5 mg/mL and the ITO-PET substrate coated with ZnO NRs was mounted in home-made cell exposing an area of 0.07 cm 2 to operate as working electrode.…”
Section: Resultsmentioning
confidence: 99%
“…In order to increase the immobilization of the primary antibody, rGO was deposited on top of the ZnO NRs using electrodeposition by applying a constant potential of -0.8 V vs SCE for 300 sec, as previously reported in [106]. GO stock solution (4 mg/ml) was dispersed in acetate buffer solution with a final concentration of 0.5 mg/mL and the ITO-PET substrate coated with ZnO NRs was mounted in home-made cell exposing an area of 0.07 cm 2 .…”
Section: Resultsmentioning
confidence: 99%