2018
DOI: 10.1049/iet-gtd.2017.0381
|View full text |Cite
|
Sign up to set email alerts
|

Reduced‐order modelling of solar‐PV generators for small‐signal stability assessment of power systems and estimation of maximum penetration levels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
27
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(27 citation statements)
references
References 33 publications
0
27
0
Order By: Relevance
“…According to [20], the mathematical model between output current i pv and output voltage v pv of the PV arrays is given by (1):…”
Section: A the Dynamics Of Front-end Circuitmentioning
confidence: 99%
See 1 more Smart Citation
“…According to [20], the mathematical model between output current i pv and output voltage v pv of the PV arrays is given by (1):…”
Section: A the Dynamics Of Front-end Circuitmentioning
confidence: 99%
“…In power systems and micro-grid, the installed capacity of renewable energy power generation has increased a lot in past decades. Renewable energy is considered as a key factor in solving energy security due to the availability of photovoltaic (PV) resources, low cost and non-pollution on environment [1]. The existing research on photovoltaic (PV)…”
Section: Introductionmentioning
confidence: 99%
“…Apart from this, other major challenge associated with renewable energy generation is the uncertainty in output power [1,2]. As reported in [3], the integration of large-scale PV plant could affect the oscillatory stability or small-signal stability due to the different dynamic characteristics and reverse power flow in the system. It is observed that the damping ratio of the electromechanical mode changed with the penetrations of large-scale PV.…”
Section: Introductionmentioning
confidence: 99%
“…The impact of HVDC on small‐signal stability is reported in [6]. The influence of large‐scale PV plants on the small‐signal stability is reported in [7]. As reported in [7], the integration of large‐scale PV plant may adversely affect the oscillatory stability of power system due to zero inertia and reverse power flow.…”
Section: Introductionmentioning
confidence: 99%
“…The influence of large‐scale PV plants on the small‐signal stability is reported in [7]. As reported in [7], the integration of large‐scale PV plant may adversely affect the oscillatory stability of power system due to zero inertia and reverse power flow. The influence of WPP penetration on small‐signal stability is reported in [8].…”
Section: Introductionmentioning
confidence: 99%