2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551)
DOI: 10.1109/pesc.2004.1355486
|View full text |Cite
|
Sign up to set email alerts
|

Reduced-switch three-phase active power filter with one cycle control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 15 publications
0
10
0
Order By: Relevance
“…A review of the topologies of AC-DC converters, such as 2L2B, used in industry for the improvement of energy quality is presented in [29]. In the studies presented in [30][31][32][33][34], the 2L2B topology is analyzed as an active shunt filter, being employed various types of control strategies in synchronous reference frame or stationary one, with different modulation techniques. A variation of the topology 2L2B shown in Figure 2a is discussed in [35][36][37] as a power hybrid filter.…”
Section: Rsc Gscmentioning
confidence: 99%
See 2 more Smart Citations
“…A review of the topologies of AC-DC converters, such as 2L2B, used in industry for the improvement of energy quality is presented in [29]. In the studies presented in [30][31][32][33][34], the 2L2B topology is analyzed as an active shunt filter, being employed various types of control strategies in synchronous reference frame or stationary one, with different modulation techniques. A variation of the topology 2L2B shown in Figure 2a is discussed in [35][36][37] as a power hybrid filter.…”
Section: Rsc Gscmentioning
confidence: 99%
“…The operation of the GSC with 2L2B topology can be analyzed similarly to a grid-connected converter operating as an active filter, due to the isolated DC link in a back-to-back configuration [30][31][32]36,38,39]. From Figure 5, (6) is derived using Kirchhoff's Voltage Law (KVL) in each phase, furthermore, the analysis considers grid voltages to be balanced and distortion-free.…”
Section: Grid-side Converter With 2l2b Topologymentioning
confidence: 99%
See 1 more Smart Citation
“…The difference of real power will result in the voltage variation of dc capacitor. Since the utility power factor is desired to be close to unity after compensation by the proposed power filter, the difference of real power can be represented as (10) where is the demanded real power of load. If is negative, it means that the supplied real power is smaller than the demanded real power, so the voltage of the dc capacitor will be reduced.…”
Section: Three-phase Three-wire Active Power Filtermentioning
confidence: 99%
“…However, the cost is higher than other methods. Conventionally, a three-phase three-wire APF, comprising a three-arm power converter or a two-arm power converter with split capacitors, is used to compensate for the harmonic currents in the three-phase three-wire distribution power system [10]- [12]. In contrast, a three-phase four-wire APF, comprising a four-arm power converter or a three-arm power converter with split capacitors, is used to compensate for the harmonic currents in the three-phase four-wire distribution power system.…”
Section: Introductionmentioning
confidence: 99%