2019
DOI: 10.1016/j.electacta.2018.10.018
|View full text |Cite
|
Sign up to set email alerts
|

Reducing subjectivity in EIS interpretation of corrosion and corrosion inhibition processes by in-situ optical analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
51
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 40 publications
(51 citation statements)
references
References 38 publications
0
51
0
Order By: Relevance
“…Optical-electrochemical setup.- Figure 1 shows the improved optical-electrochemical setup used in this work derived from our previous studies. 17,18 The current and potential signals for EN were recorded with an Ivium Compactstat using IviumSoft V2.86. The electrochemical current noise (ECN) was measured between the two parallel working electrodes (see sample preparation) with the Compactstat acting as zero resistance ammeter (ZRA).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Optical-electrochemical setup.- Figure 1 shows the improved optical-electrochemical setup used in this work derived from our previous studies. 17,18 The current and potential signals for EN were recorded with an Ivium Compactstat using IviumSoft V2.86. The electrochemical current noise (ECN) was measured between the two parallel working electrodes (see sample preparation) with the Compactstat acting as zero resistance ammeter (ZRA).…”
Section: Methodsmentioning
confidence: 99%
“…Compared to the setup used in our previous works, 18 a new geometry of the optical-electrochemical cell was used for the alignment of the high-resolution microscope. Two different magnification cameras from Dino-Lite with a 5.0 megapixel CMOS sensor (2592 × 1944 pixels) were used.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The validated contact probe is directly applied on an outdoor surface, such as the nineteenth statue of Napoleon located in Milan, to evaluate the efficiency of the restoration treatments [29,41,42,43]. In situ experimental results were comparable to those observed in the laboratory from bronze coupon samples [3,26,39,40,41]. In particular, |Z| is the measured parameter that resulted in a 10 mHz value, after in situ experiments, meaning that different areas showed different values of corrosion susceptibility.…”
Section: Electrochemical Impedance Spectroscopy In Chmentioning
confidence: 99%
“…Due to the presence of the thiol group in the structure of the DEDTC, which also was found in very active corrosion inhibitors, this compound have a potential application to be used as an inexpensive corrosion inhibitor for the AA2024-T3 [45][46][47] . Ferrer et al 48 used the NaY zeolite particles double-doped with cerium and diethyldithiocarbamate (DEDTC) to improve the corrosion inhabitation of the AA2024-T3 in saline solution.…”