2014
DOI: 10.1016/j.enconman.2013.09.033
|View full text |Cite
|
Sign up to set email alerts
|

Reducing the energy consumption of an earth–air heat exchanger with a PID control system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 18 publications
0
8
0
Order By: Relevance
“…Generally, the inputs of PID controller are the reference point and controller output. In [78], the PID controller takes input as the temperature difference between the surrounding air and the ground for cooling or heating the air to control the earth-air heat exchanger, leading to a reduction of energy consumption up to 87%. Besides, the PID controller has been successfully implemented in various sections in buildings such as light control [79] power tracking performance improvement [80] and vibration control [81] and energy consumption reduction [78].…”
Section: ()mentioning
confidence: 99%
See 1 more Smart Citation
“…Generally, the inputs of PID controller are the reference point and controller output. In [78], the PID controller takes input as the temperature difference between the surrounding air and the ground for cooling or heating the air to control the earth-air heat exchanger, leading to a reduction of energy consumption up to 87%. Besides, the PID controller has been successfully implemented in various sections in buildings such as light control [79] power tracking performance improvement [80] and vibration control [81] and energy consumption reduction [78].…”
Section: ()mentioning
confidence: 99%
“…In [78], the PID controller takes input as the temperature difference between the surrounding air and the ground for cooling or heating the air to control the earth-air heat exchanger, leading to a reduction of energy consumption up to 87%. Besides, the PID controller has been successfully implemented in various sections in buildings such as light control [79] power tracking performance improvement [80] and vibration control [81] and energy consumption reduction [78]. Although P, PI, and PID are closed-loop/feedback control systems, their performance is not reasonable in noisy and non-linear processes due to the poor control performance, thus resulting in significant time delays [82] [83] [84].…”
Section: ()mentioning
confidence: 99%
“…Shen et al (2014) and Beier (2014) have studied the cooling performance of heat exchangers using dynamic changes. Dynamic studies can also be used to develop control strategies for reducing the energy consumption (Diaz-Mendez et al, 2014;Ibrahim et al, 2014). The importance of developing heat exchange programming for reactors was presented by Fu and Xu (2013) and Henini et al (2013).…”
Section: Introductionmentioning
confidence: 99%
“…On-off and proportional, integral and derivative (PID) control strategy has been widely used in industrial control process. In particular, PID control strategy has gained an extensive application in various thermal engineering systems, for instance, heat exchanger [1], refrigeration system [2] [3] and heating, ventilation and air-conditioning (HVAC) system [4] [5]. In these previous researches, controller based on PID control strategy has simple structure and effective control has been achieved.…”
Section: Introduction 1conventional Pid Controllermentioning
confidence: 99%