2019
DOI: 10.1039/c9ra07058c
|View full text |Cite
|
Sign up to set email alerts
|

Reducing uncertainty in simulation estimates of the surface tension through a two-scale finite-size analysis: thicker is better

Abstract: Recent simulation studies of the surface tension , and other properties of thin freestanding films, have revealed unexpected finite size effects in which the variance of the properties vary monotonically with the in-plane width of the films, complicating the extrapolation of estimates of film properties to the thermodynamic limit. We carried out molecular dynamics simulations to determine the origin of this phenomenon, and to address the practical problem of developing a more reliable methodology for estimatin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 33 publications
2
7
0
Order By: Relevance
“…From this point onwards, the external driving force and the electric field are applied to the flow, and results are saved and averaged for three or four consecutive runs of 5 ns each (larger channels demand more time to reach steady flow). This simulation duration is expected to yield equilibrated results, as also shown in another studies [50][51][52].…”
Section: Channel Descriptionsupporting
confidence: 72%
“…From this point onwards, the external driving force and the electric field are applied to the flow, and results are saved and averaged for three or four consecutive runs of 5 ns each (larger channels demand more time to reach steady flow). This simulation duration is expected to yield equilibrated results, as also shown in another studies [50][51][52].…”
Section: Channel Descriptionsupporting
confidence: 72%
“…Chains of 200 carbon units were chosen as a tradeoff between computation time and chain size; larger chains required a larger A i to find the t c . The chosen A i is not large enough to avoid size effects; based on the results for atomistic systems at a T close to the triple point, a simulation cell ~20 times larger the lateral length used in this work is needed to minimize the size effects [8,14]; it is estimated that our calculations for t c will have underpredictions of ~30% at temperatures close to the shifted T m .…”
Section: Methodsmentioning
confidence: 99%
“…Due to computational limitations, molecular simulations of thin layers are commonly carried out in simulation cells with very small interfacial areas, A i , in the scale of a few nm 2 , where the full extent of the capillary waves cannot manifest. Simulations on A i as large as 600 nm × 600 nm [14] did not develop capillary waves or other thermal fluctuations large enough to break the films; therefore, other phenomena should arise at this peculiar state. Additionally, other phenomena occur as the thickness of the layer is reduced.…”
Section: Introductionmentioning
confidence: 94%
“…The pressure proles were obtained by calculating the pressure tensors in each slab, using Harasima pressure proles 40,41 implemented in LAMMPS. 42 The proles were calculated for every 100 timesteps (10 5 proles), and the proles were averaged, correcting the proles through the center of the layer, which was calculated as the midpoint between the Gibbs dividing surfaces, which were obtained tting the total density proles to an expression dependent on the separation to the interfaces in the normal direction, z: 43,44…”
Section: Computational Detailsmentioning
confidence: 99%
“…The two-peak zone at temperatures below the thermal limit is associated with zones of different cohesivity-an outermost, external interfacial zone (negative peak), where the bulk liquid zone strongly attracts chains of cations in ionic liquids, 56 chains in alkanes and polymers, 45 or atoms in atomic systems. 43,44 Interactions between the outermost cohesive zone and the bulk liquid create an intermediate crunched zone, which manifests as the positive peak. Starting at 673.15 K, the outermost external negative peak of P n shows values lower than those of the bulk liquid, probably indicating how metastable the systems are at these temperatures.…”
Section: Pressure Proles and Surface Tensionmentioning
confidence: 99%