2008
DOI: 10.1016/j.nuclcard.2007.09.029
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of infracardiac intestinal activity by a small amount of soda water in technetium-99m tetrofosmin myocardial perfusion scintigraphy with adenosine stress

Abstract: The intake of 100 mL of soda water improves intestinal activity and improves the image quality of the inferior wall.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
28
1
1

Year Published

2009
2009
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(32 citation statements)
references
References 9 publications
2
28
1
1
Order By: Relevance
“…The I/A count ratio was significantly higher in the soda water cohort (1.9 ± 0.51) compared with the control group (1.5 ± 0.35, p < 0.0001). In addition, three-dimensional computed tomography was performed in both groups and volumetric analysis of gastric distention was performed demonstrating a substantial increase in gastric volume from 55.9 to 276.6 ml with soda water administration [Hara et al 2008]. We present the largest patient population to date examining the use of soda water prior to both stress and resting Tc-99m SPECT imaging.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The I/A count ratio was significantly higher in the soda water cohort (1.9 ± 0.51) compared with the control group (1.5 ± 0.35, p < 0.0001). In addition, three-dimensional computed tomography was performed in both groups and volumetric analysis of gastric distention was performed demonstrating a substantial increase in gastric volume from 55.9 to 276.6 ml with soda water administration [Hara et al 2008]. We present the largest patient population to date examining the use of soda water prior to both stress and resting Tc-99m SPECT imaging.…”
Section: Discussionmentioning
confidence: 99%
“…water in MPI [Hara et al 2008]. We sought to examine the incidence of gastric activity in our institution prior to and after implementation of soda water in 467 consecutive MPI studies.…”
mentioning
confidence: 99%
“…Quantification of the inferior wall-to-abdomen (I/A) count ratio was performed as described previously [5]. The ROI sizes were five pixels in diameter and were identical in every patient.…”
Section: Quantification Of Inferior Wall-to-abdomen Count Ratiomentioning
confidence: 99%
“…Hara et al [5] showed another approach to increase stomach volume using carbon dioxide gas in patients undergoing pharmacological stress (adenosine). In the present randomized study, we compared the effects of carbonated water, which releases carbon dioxide gas, with those of still water in patients scheduled to undergo exercise myocardial SPECT, adenosine myocardial SPECT and rest myocardial SPECT.…”
Section: Introductionmentioning
confidence: 99%
“…Attenuation artifacts are a problem in the accurate evaluation of myocardial perfusion scintigraphy. The left anterior-lateral attenuation artifact depending on breast tissue in female and inferior walls attenuation artifact due to diaphragm in men can lead to false positive evaluation on myocardial perfusion SPECT [4][5][6][7][8][9][10][11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%