2016 IEEE Energy Conversion Congress and Exposition (ECCE) 2016
DOI: 10.1109/ecce.2016.7855384
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of input current harmonics based on space vector modulation for three-phase VSI with varied power factor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…Simulation results are presented in Figure 8. The peak-to-peak envelopes calculated by Equation (19) as the half of peak-to-peak dc-link voltage ripple amplitude ∆vpp/2(t) (red traces) are shown together with the instantaneous dc-link voltage switching ripple ∆v(t) (blue trace) over a funda- Simulation results are presented in Figure 8. The peak-to-peak envelopes calculated by Equation 19 Simulation results are presented in Figure 8.…”
Section: Numerical and Experimental Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Simulation results are presented in Figure 8. The peak-to-peak envelopes calculated by Equation (19) as the half of peak-to-peak dc-link voltage ripple amplitude ∆vpp/2(t) (red traces) are shown together with the instantaneous dc-link voltage switching ripple ∆v(t) (blue trace) over a funda- Simulation results are presented in Figure 8. The peak-to-peak envelopes calculated by Equation 19 Simulation results are presented in Figure 8.…”
Section: Numerical and Experimental Resultsmentioning
confidence: 99%
“…The peak-to-peak envelopes calculated by Equation 19 Simulation results are presented in Figure 8. The peak-to-peak envelopes calculated by Equation (19) as the half of peak-to-peak dc-link voltage ripple amplitude ∆vpp/2(t) (red traces) are shown together with the instantaneous dc-link voltage switching ripple ∆v(t) (blue trace) over a funda- Figure 8. In all screenshots, two upper traces present the load voltage and current (green and red traces, respectively) and the bottom (blue) trace presents the measured dc-link voltage switching ripple ∆v(t).…”
Section: Numerical and Experimental Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Since DC-link capacitor accounts for a large part of the inverter system size, optimising its size is a key goal for inverter system design. Based on the two-level VSI, some researchers have proposed optimised space vector pulse modulation to reduce the DC-link RMS current [10][11][12]. Comparing the classical spacevector modulation, the proposed method uses the non-adjacent voltage vector to decrease the RMS current in each switching period.…”
Section: Introductionmentioning
confidence: 99%