1990
DOI: 10.1016/0167-6105(90)90415-9
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of wind induced motion utilizing a tuned sloshing damper

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The tuned sloshing damper (TSD) is a well-established vibration control device that has been used to study mitigation of structural responses due to various environmental excitations from wind, waves, and earthquake (Lee and Reddy, 1982; Kareem, 1990; Modi and Seto, 1997; Banerji et al., 2000; Jin et al., 2007; Nanda and Biswal, 2011; Murudi and Banerji, 2012; Roy et al., 2017). There have been a number of practical implementations of TSDs, chiefly for wind-excited tall buildings, airport towers, commercial towers, skyscrapers, and bridges (Tamura et al., 1995; Soong and Dargush, 1997; Malekghasemi et al., 2015).…”
Section: Introductionmentioning
confidence: 99%
“…The tuned sloshing damper (TSD) is a well-established vibration control device that has been used to study mitigation of structural responses due to various environmental excitations from wind, waves, and earthquake (Lee and Reddy, 1982; Kareem, 1990; Modi and Seto, 1997; Banerji et al., 2000; Jin et al., 2007; Nanda and Biswal, 2011; Murudi and Banerji, 2012; Roy et al., 2017). There have been a number of practical implementations of TSDs, chiefly for wind-excited tall buildings, airport towers, commercial towers, skyscrapers, and bridges (Tamura et al., 1995; Soong and Dargush, 1997; Malekghasemi et al., 2015).…”
Section: Introductionmentioning
confidence: 99%
“…However, most of these studies focus on the application of rectangular and cylindrical TLDs and a limited knowledge on the behavior of annular TLDs is available in the literature. Pioneering bodies of research on the experimental and numerical investigation of TLDs were carried out by Fujino et al (1988), Sun et al (1989) and, Kareem (1990), Fujii et al (1990), Tamura et al (1992), Wakahara et al (1992), Fujino et al (1992), Zhang et al (1993), Zhao and Fujino (1993), Fujino and Sun (1993), Sun and Fujino (1994), Nomura (1994), Sun et al (1995a,b), Tamura et al (1995), Chen et al (1995), Fediw et al (1995), and Koh et al (1995). Most of these works were concerned with rectangular and cylindrical TLDs.…”
Section: Introductionmentioning
confidence: 99%
“…These excitations depend on various factors such as intensity of wind loads, and size, shape, and dynamic properties of the building (Simiu, 1996). Various methods for mitigation of wind-induced excitations have been investigated (Kareem, 1990;Kareem et al, 1999;Soong, 1997). One of them adds an auxiliary damping device to the main building to increase damping and consequently decrease excitations (Den Hartog, 1934;Warburton and Ayorinde, 1980;Ayorinde and Warburton, 1980;Kareem and Kline, 1995).…”
Section: Introductionmentioning
confidence: 99%