2006
DOI: 10.1002/uog.2857
|View full text |Cite
|
Sign up to set email alerts
|

Reference data representative of normal findings at three‐dimensional power Doppler ultrasound examination of the cervix from 17 to 41 gestational weeks

Abstract: Objectives To develop normal reference ranges for cervical volume and vascular indices using threedimensional (3D) power [17][18][19][20][21][22][23][24][25][26][27][28][29][30] P < 0.0001; median VFI 1.6 vs. 0.9, P < 0.0001

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
35
0
7

Year Published

2006
2006
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(45 citation statements)
references
References 11 publications
3
35
0
7
Order By: Relevance
“…Vaginal ultrasonography produces good images and is well accepted by patients. There are no apparent risks associated with the examination [53][54][55][56]. In contrast, transvaginal ultrasonography is a reproducible method of examination during pregnancy.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Vaginal ultrasonography produces good images and is well accepted by patients. There are no apparent risks associated with the examination [53][54][55][56]. In contrast, transvaginal ultrasonography is a reproducible method of examination during pregnancy.…”
Section: Discussionmentioning
confidence: 99%
“…The length of the cervix is directly correlated with the duration of pregnancy: the shorter the cervix, the greater the likelihood of preterm delivery. This is mainly because uterine contractions, whether perceived by the woman or not, shorten the cervix [53][54][55][56][57][58][59][60]. [61].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Transvaginal sonography was carried out by a single operator (L.R.) using the same technique as described in detail elsewhere 12,13 . The equipment used was a GE Voluson 730 Expert ultrasound system (GE Healthcare, Zipf, Austria) equipped with a 2.8-10-MHz transvaginal transducer.…”
Section: Methodsmentioning
confidence: 99%
“…Cervical volume (cm 3 ) and power Doppler flow indices, i.e. vascularization index (VI), flow index (FI) and vascularization flow index (VFI), were calculated using the Virtual Organ Computeraided AnaLysis software (VOCAL TM ) 12,13 . All ultrasound results were unavailable to the clinical staff.…”
Section: Methodsmentioning
confidence: 99%