2008
DOI: 10.1038/eye.2008.292
|View full text |Cite
|
Sign up to set email alerts
|

Reference intervals and discrimination values of the Lanthony desaturated D-15 panel test in young to middle-aged Japanese army officials: the Okubo Color Study Report 1

Abstract: Purpose To better understand the reference values and adequate discrimination values of colour vision function with described quantitative systems for the Lanthony desaturated D-15 panel (D-15DS). Methods A total of 1042 Japanese male officials were interviewed and underwent testing using Ishihara pseudoisochromatic plates, standard pseudoisochromatic plates part 2, and the D-15DS. The FarnsworthMunsell (F-M) 100-hue test and the criteria of Verriest et al were used as definitive tests. Outcomes of the D-15DS … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…This outcome contradicts the Okubo Study Report 1 and 2 in which ICV was associated with elevated LDL-C and systolic and diastolic blood pressures. However, the Okubo study included both healthy participants and those without T2DM and its cross-sectional method did not permit any observation of biochemical trend and progression of its participants clinical conditions [ 16 , 17 ]. In the SNDREAMS- II 3rd Report, HDL-C was higher in the non-ICV group [ 5 ].…”
Section: Discussionmentioning
confidence: 99%
“…This outcome contradicts the Okubo Study Report 1 and 2 in which ICV was associated with elevated LDL-C and systolic and diastolic blood pressures. However, the Okubo study included both healthy participants and those without T2DM and its cross-sectional method did not permit any observation of biochemical trend and progression of its participants clinical conditions [ 16 , 17 ]. In the SNDREAMS- II 3rd Report, HDL-C was higher in the non-ICV group [ 5 ].…”
Section: Discussionmentioning
confidence: 99%
“…Macular architecture and BluePeak blue laser autofluorescence imaging were studied using SD‐OCT (Spectralis, Heidelberg Engineering GmbH, Heidelberg, Germany). Colour vision was assessed with Lanthony desaturated D‐15 test, more than one diametrical crossing was considered as abnormal (Shoji et al 2009).…”
Section: Methodsmentioning
confidence: 99%
“…The study was reviewed by the National Defense Medical College (NDMC) Ethics Board to ensure that it met ethical guidelines, and all subjects provided written informed consent according to the Declaration of Helsinki, prior to participating in the study. The detailed design of the study has been previously described [12,13]. In brief, this study was a prevalence survey of colour vision impairment among male officials who were between 20 and 60 years of age and on active duty in the Japanese Self Defense Force (JSDF), Okubo Garrison, Kyoto, Japan.…”
Section: Methodsmentioning
confidence: 99%