2020
DOI: 10.1097/aud.0000000000000954
|View full text |Cite
|
Sign up to set email alerts
|

Refining Measurements of Power Absorbance in Newborns: Probe Fit and Intrasubject Variability

Abstract: Because unresolved debris in the ear canal or middle ear of newborns may produce high false positive rates on hearing screening tests, it has been suggested that an outer/middle ear measure can be included at the time of hearing screening. A potential measure is power absorbance (absorbance), which indicates the proportion of power in a broadband acoustic stimulus that is absorbed through the outer/middle ear. Although absorbance is sensitive to outer/middle dysfunction at birth, there is large variability tha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(14 citation statements)
references
References 32 publications
0
14
0
Order By: Relevance
“…To illustrate the use of normative WBA area, a subset of the data that were previously described by AlMakadma and Prieve 38 were used for the construction of normative WBA area plots. The 10th and 90th percentile values were computed using 532 WBA repeated measurements from 84 newborn ears with normal hearing, indicated by transient-evoked OAE (TEOAE) hearing screening tests.…”
Section: Wideband Power Absorbance In Normal Earsmentioning
confidence: 99%
See 4 more Smart Citations
“…To illustrate the use of normative WBA area, a subset of the data that were previously described by AlMakadma and Prieve 38 were used for the construction of normative WBA area plots. The 10th and 90th percentile values were computed using 532 WBA repeated measurements from 84 newborn ears with normal hearing, indicated by transient-evoked OAE (TEOAE) hearing screening tests.…”
Section: Wideband Power Absorbance In Normal Earsmentioning
confidence: 99%
“…55 In newborns, loose probe fitting has been associated with large artificial increase in absorbance at frequencies < 1,000 Hz, and smaller but significant increases at frequencies between 1,000 and 6,000 Hz. 38 Such artificial increases may negatively impact clinical assessment of sound conduction; for example, a measurement with poor fitting maybe erroneously classified as normal due to artificially increased absorbance into the normal range, whereas in fact the sound conduction in the outer/middle ear may be abnormal.…”
Section: Loose Probe-tip Fitting and Artificial Increase In Absorbancementioning
confidence: 99%
See 3 more Smart Citations