2014
DOI: 10.1016/j.jcrs.2013.06.029
|View full text |Cite
|
Sign up to set email alerts
|

Refractive surprise after toric intraocular lens implantation: Graph analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
15
0
3

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(19 citation statements)
references
References 16 publications
1
15
0
3
Order By: Relevance
“…As described above, in a procedure in which the natural lens has been removed, the refractive outcome can be analyzed as either the procedure as a whole or based on the lens in isolation. To achieve this, further vector analysis can be done using the hybrid method as described by Alpins et al 10 In this method, the preoperative astigmatism is taken to be the corneal astigmatism after including the predicted effect of the corneal incision, so that the refractive cylindrical correction of the IOL is isolated from the astigmatic effect of the corneal incision, which has already been handled separately and described above. The postoperative astigmatism is then taken to be manifest refractive cylinder (adjusted to the corneal plane).…”
Section: Toric Iols: Guide For Advanced Graphical Analysismentioning
confidence: 99%
“…As described above, in a procedure in which the natural lens has been removed, the refractive outcome can be analyzed as either the procedure as a whole or based on the lens in isolation. To achieve this, further vector analysis can be done using the hybrid method as described by Alpins et al 10 In this method, the preoperative astigmatism is taken to be the corneal astigmatism after including the predicted effect of the corneal incision, so that the refractive cylindrical correction of the IOL is isolated from the astigmatic effect of the corneal incision, which has already been handled separately and described above. The postoperative astigmatism is then taken to be manifest refractive cylinder (adjusted to the corneal plane).…”
Section: Toric Iols: Guide For Advanced Graphical Analysismentioning
confidence: 99%
“…В ряде работ описан феномен так называемого «реф-ракционного сюрприза», при котором после проведен-ной операции повторно измеряли аксиальную ось глаза и пересчитывали оптическую силу ИОЛ, после чего фик-сировали разницу в значениях расчетной и действитель-ной рефракции [11,12,13]. Среди причин «рефракцион-ного сюрприза» авторы выделяют неправильную размет-ку торической ИОЛ, возможную ошибку в оптике ИОЛ и некорректное ELP (положение линзы) [12,13].…”
Section: имплантация «Piggyback» иол или замена иол?unclassified
“…Среди причин «рефракцион-ного сюрприза» авторы выделяют неправильную размет-ку торической ИОЛ, возможную ошибку в оптике ИОЛ и некорректное ELP (положение линзы) [12,13]. При этом, по мнению Solebo и соавт., имплантация «piggyback» ИОЛ предпочтительнее, так как рефракционная замена ИОЛ может привести к повторному «рефракционному сюрпризу» [13].…”
Section: имплантация «Piggyback» иол или замена иол?unclassified
“…A A variety of techniques and software analyses are available to assist in toric IOL repositioning. 9 In our cases, we used the online software created by Drs. Berdahl and Hardten.…”
mentioning
confidence: 99%