1995
DOI: 10.1016/0890-4332(95)90063-2
|View full text |Cite
|
Sign up to set email alerts
|

Regenerative adsorption heat pumps: Optimization of the design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0

Year Published

1997
1997
2021
2021

Publication Types

Select...
3
2
2

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(17 citation statements)
references
References 8 publications
1
16
0
Order By: Relevance
“…Most of the times, the zeolite#water pair is used in cooling systems with closed cycle where the water vapour is at low pressure, e.g. some kilopascal (Grenier et al, 1988;Douss et al, 1988;Ben Chanaa et al, 1991;Zhu et al, 1992;van Benthem et al, 1995;Hajji and Khallou", 1995;Guilleminot et al, 1998). Some solar systems operated with the silicagel#water pair have also been tested (Dupont et al, 1994;Gurgel and Kluppel, 1996).…”
Section: Introductionmentioning
confidence: 98%
“…Most of the times, the zeolite#water pair is used in cooling systems with closed cycle where the water vapour is at low pressure, e.g. some kilopascal (Grenier et al, 1988;Douss et al, 1988;Ben Chanaa et al, 1991;Zhu et al, 1992;van Benthem et al, 1995;Hajji and Khallou", 1995;Guilleminot et al, 1998). Some solar systems operated with the silicagel#water pair have also been tested (Dupont et al, 1994;Gurgel and Kluppel, 1996).…”
Section: Introductionmentioning
confidence: 98%
“…The calculations were performed using the following parameters: hw = 1500 W/m e K, hf = 1000 W/m e K, negligible Sin/kin, S. In order to have an idea about the quantitative influence of the ~ value on the machine performance, the specific power in the heating mode has been calculated using a simulation program developed in Ref. [15]. The model refers to an adsorption heat pump composed of two reactors with a uniform temperature distribution and operation with the internal heat recovery.…”
Section: Resultsmentioning
confidence: 99%
“…As expected, these models can be used to obtain a theoretical limit regarding performance and capacity of a system, but are not able to identify causes of poor performance when examining experimental data. Several thermodynamic models can be found in the literature [33,34,35,36].…”
Section: Review Of Mathematical Modelsmentioning
confidence: 99%
“…Cacciola et al [34] The optimization of the design of an adsorption heat pump based on thermodynamic analysis was investigated by Cacciola et al [35] and Benthem et al [36].…”
Section: Thermodynamic Modelsmentioning
confidence: 99%
See 1 more Smart Citation