Regional Quality Control Survey of Blood-Gas Analysis

Abstract: We undertook an external quality control survey of blood-gas analysis in 16 laboratories at 13 hospitals. All samples were prepared in the laboratories under investigation by equilibration of blood or serum with gas mixtures of known composition. pH of serum was measured with no significant bias but with an SD of random error 0·026 pH units, which was almost twice the SD of the reference range (0·015). An acceptable random error (half SD of reference range) was not obtained in a longitudinal internal quality c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
7
0

Year Published

1978
1978
2008
2008

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 22 publications
3
7
0
Order By: Relevance
“…These results are similar to those obtained for all participants, shown in Tables I to 3, confirming the observation of Minty and Nunn (1977) that instruments used outside clinical chemistry laboratories do not exhibit worse performance than those in departments of clinical chemistry. It must be realised, however, that laboratories participated voluntarily in these surveys, and those laboratories with a greater awareness of quality control and desire to check the comparability of their results would therefore tend to be selected preferentially.…”
Section: No Of Resultssupporting
confidence: 89%
See 2 more Smart Citations
“…These results are similar to those obtained for all participants, shown in Tables I to 3, confirming the observation of Minty and Nunn (1977) that instruments used outside clinical chemistry laboratories do not exhibit worse performance than those in departments of clinical chemistry. It must be realised, however, that laboratories participated voluntarily in these surveys, and those laboratories with a greater awareness of quality control and desire to check the comparability of their results would therefore tend to be selected preferentially.…”
Section: No Of Resultssupporting
confidence: 89%
“…The CVs observed for [H+], PC02, and P02 are approximately double those reported in withinlaboratory trials using similar materials assayed over several weeks on one instrument (Evans, 1978;Minty and Nunn, 1977). This difference between within-laboratory precision and total betweenlaboratory, between-instrument precision is similar to that observed for many other analytes (Whitehead et al, 1973) and suggests that neither the materials used in this study nor the present state of [H +] and blood gas analysis is poor with regard to precision.…”
Section: Discussionsupporting
confidence: 66%
See 1 more Smart Citation
“…4KOll, cision control for pH measurements and an accuracy 4KOIO, 4KOO9). The same measurements were also and precision controlfor Pcos and Posmeasurements made on a tonometered phosphate-bicarbonate- (Bird and Henderson, 1971;Minty and Nunn, 1977). chloride solution in a glycerol-water mixture (4) A buffer made up in glycerol-water mixtures and (Veefkind et al, 1975).…”
mentioning
confidence: 99%
“…A recent study (Minty and Nunn, 1977) has supplied data on the levels of accuracy attained in a sample of 16 laboratories in the north-west region of the UK. The study involved the analysis of blood of known P02 and PC02 and serum of known pH.…”
Section: B Minty Northwick Park Hospital Harrow Middlesexmentioning
confidence: 99%