2002
DOI: 10.3109/10929080209146037
|View full text |Cite
|
Sign up to set email alerts
|

Registration Accuracy and Practicability of Laser-Directed Surface Matching

Abstract: The aim of our study was to evaluate the registration accuracy and practicability of a new laser registration technique in comparison to marker registration. From January to August 2001, 36 patients (23 male, 13 female) with brain lesions were operated with navigational guidance. Thirty-five patients were registered by paired-point registration. In 16 patients, a second registration was carried out using a special laser pointer for surface matching (z-touch trade mark, BrainLab, Heimstetten, Germany). Accuracy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
64
2
1

Year Published

2007
2007
2014
2014

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 95 publications
(71 citation statements)
references
References 19 publications
4
64
2
1
Order By: Relevance
“…Our results are also comparable with those for other registration methods such as laser surface scanning, boneimplanted fiduciary markers, and anatomical structures (Schlaier et al, 2002;Marmulla et al, 2004a;Hoffmann et al, 2005b;Hardy et al, 2006;Pham et al, 2007). The use of a CBCT dataset seems to lead to the same results as those obtained with a CT dataset (Eggers et al, 2009).…”
Section: Discussionsupporting
confidence: 82%
See 1 more Smart Citation
“…Our results are also comparable with those for other registration methods such as laser surface scanning, boneimplanted fiduciary markers, and anatomical structures (Schlaier et al, 2002;Marmulla et al, 2004a;Hoffmann et al, 2005b;Hardy et al, 2006;Pham et al, 2007). The use of a CBCT dataset seems to lead to the same results as those obtained with a CT dataset (Eggers et al, 2009).…”
Section: Discussionsupporting
confidence: 82%
“…Previous studies have evaluated general precision (Schlaier et al, 2002;Hoffmann et al, 2005b;Metzger et al, 2007) and concentrated on navigation precision in the maxillary and periorbital region (Marmulla et al, 2004b;Marmulla et al, 2004a;Hardy et al, 2006) or precision in the cranium (Luebbers et al, 2008).…”
Section: Introductionmentioning
confidence: 99%
“…The SNN++ system has to calculate one additional transformation to match the coordinate system of the laser scanner and the that of the infrared camera. However, reports in literature showed a considerably less accurate registration with the z-touch system than was achieved in our study [36]. On the one hand this is explained the lower number of recorded points (ztouch: hundreds of points, SNN++ approx.…”
Section: Discussioncontrasting
confidence: 49%
“…These have to be interpreted very carefully because the study design excluded the influence of soft tissue movements, and those are supposed to have the biggest impact on precision of surface matching techniques. However, our clinical experiences as well as the numerous studies do suggest acceptable accuracy for laser surface matching (Marmulla et al, 1997a;Raabe et al, 2002;Schlaier et al, 2002;Marmulla et al, 2003;Troitzsch et al, 2003;Marmulla et al, 2004a;Marmulla et al, 2004b;Marmulla et al, 2004c;Hoffmann et al, 2005;Marmulla et al, 2005a). This technique very often does not need additional 3D imaging for surgical navigation and has no need of preoperative invasive procedures in order to prepare the patient for the computerassisted surgery.…”
Section: Laser Surface Scanningmentioning
confidence: 70%