1999
DOI: 10.1118/1.598671
|View full text |Cite
|
Sign up to set email alerts
|

Registration and warping of magnetic resonance images to histological sections

Abstract: We present a method for coregistration and warping of magnetic resonance images (MRI) to histological sections for comparison purposes. This methodology consists of a modified head and hat surface-based registration algorithm followed by a new automated warping approach using nonlinear thin plate splines to compensate for distortions between the data sets. To test the methodology, 15 male Wistar rats were subjected to focal cerebral ischemia via permanent occlusion of the middle cerebral artery. The MRI images… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
97
1

Year Published

2000
2000
2015
2015

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 100 publications
(98 citation statements)
references
References 47 publications
0
97
1
Order By: Relevance
“…Eigentool has a comprehensive set of functions for displaying, restoring, enhancing, and analyzing images. The complete toolbox consists of image analysis algorithms such as morphological operators, registration, and warping methods (38).…”
Section: Mri Studiesmentioning
confidence: 99%
“…Eigentool has a comprehensive set of functions for displaying, restoring, enhancing, and analyzing images. The complete toolbox consists of image analysis algorithms such as morphological operators, registration, and warping methods (38).…”
Section: Mri Studiesmentioning
confidence: 99%
“…Many previous studies in MRI and histology registration (see Table 3 2004; Meyer et al, 2006;Lebenberg et al, 2010;Schormann et al, 1995;Yelnik et al, 2007;Osechinskiy and Kruggel, 2011;Bardinet et al, 2002), and furthermore many previous studies included evaluation on only one dataset (Malandain et al, 2004;Choe et al, 2011;Meyer et al, 2006;Schormann et al, 1995;Kim et al, 2000;Yelnik et al, 2007;Osechinskiy and Kruggel, 2011;Bardinet et al, 2002;Lazebnik et al, 2003). Of the studies that did report accuracy on more than one dataset, TRE ranged from sub-millimeter (Ceritoglu et al, 2010;Jacobs et al, 1999;Yang et al, 2012) to 3-5 mm (Liu et al, 2012;Singh et al, 2008). Techniques that reported sub-millimeter TRE were applied on either whole brain sections of rodents or serially sectioned histology of primates, thus the smaller scale of anatomy and lack of variable resection boundaries can explain the lower TRE relative to our method.…”
Section: Discussionmentioning
confidence: 99%
“…In the past two decades, there have also been many studies specifically dealing with in-vivo brain MRI to post-mortem histology. The majority of these studies focused on primates (Dauguet et al, 2007;Malandain et al, 2004;Breen et al, 2005;Ceritoglu et al, 2010;Choe et al, 2011) or rodents (Jacobs et al, 1999;Humm et al, 2003;Meyer et al, 2006;Lebenberg et al, 2010;Yang et al, 2012;Liu et al, 2012). The few studies that registered human brain MRIto histology were performed on wholebrain (Schormann et al, 1995;Kim et al, 2000;Singh et al, 2008), or single hemisphere (Yelnik et al, 2007;Osechinskiy and Kruggel, 2011) post-mortem serially sectioned data (Amunts et al, 2013) created a 3D model of single subject's brain using post-mortem histological sections reconstructed at 20 m isotropic resolution and registered it to a T1 average atlas created from 24 subjects.…”
Section: Introductionmentioning
confidence: 99%
“…Previous work to co-register in-vivo MRIs to microscopically examined samples has been reported mostly for small animal studies [Jacobs et al 1999;Jiang et al 2004;Meyer et al 2006;Anderson et al 2006], a limited number of primates [Malandain et al 2004;Kaufman et al 2005;Dauguet et al 2007] and relatively few human studies [Schormann et al 1995;Mega et al 1997;Toga et al 1999;Kenwright et al 2003]. Most studies involve brain imaging.…”
Section: Introductionmentioning
confidence: 99%
“…Most studies involve brain imaging. One of the earlier animal studies was based on a two-step approach where a surface-matching initial co-registration was followed by a nonlinear thin plate splines based warping [Jacobs et al, 1999]. Subsequent studies have relied mostly on maximizing mutual information [Jiang et al, 2004;Meyer et al, 2006] or an image intensity based non-rigid registration [Anderson et al, 2006].…”
Section: Introductionmentioning
confidence: 99%