Regular Insulin Administered With the V-Go Disposable Insulin Delivery Device in a Clinical Diabetes Setting: A Retrospective Analysis of Efficacy and Cost

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 13 publications
2
4
0
Order By: Relevance
“…Patients in the V-Go group reported a 24% reduction in TDD U/day and a 25% reduction in TDD U/kg while patients in the STO group reported no changes in TDD. Our observation of decreased insulin utilization after initiation of V-Go is consistent with previous research 8, [18][19][20]22 and supports the theory that continuous insulin infusion may be more efficient than insulin delivery via single or multiple injections. 14,18 Patients in the V-Go as well as the STO group were generally satisfied with their insulin delivery device at baseline and EOS, with average TRIM-Diabetes Device scores in the 70s and 80s on a 100-point scale.…”
Section: Discussionsupporting
confidence: 92%
See 3 more Smart Citations
“…Patients in the V-Go group reported a 24% reduction in TDD U/day and a 25% reduction in TDD U/kg while patients in the STO group reported no changes in TDD. Our observation of decreased insulin utilization after initiation of V-Go is consistent with previous research 8, [18][19][20]22 and supports the theory that continuous insulin infusion may be more efficient than insulin delivery via single or multiple injections. 14,18 Patients in the V-Go as well as the STO group were generally satisfied with their insulin delivery device at baseline and EOS, with average TRIM-Diabetes Device scores in the 70s and 80s on a 100-point scale.…”
Section: Discussionsupporting
confidence: 92%
“…Patients in the V-Go group reported a 24% reduction in TDD U/day and a 25% reduction in TDD U/kg while patients in the STO group reported no changes in TDD. Our observation of decreased insulin utilization after initiation of V-Go is consistent with previous research 8 , 18 20 , 22 and supports the theory that continuous insulin infusion may be more efficient than insulin delivery via single or multiple injections. 14 , 18 …”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“… 21 24–28 Although the V-Go device is currently indicated for use with U-100 RAI analogues, studies have shown that U-100 HRI is stable in V-Go devices 29 with demonstrated efficacy and safety in a small retrospective evaluation. 30 …”
Section: Introductionmentioning