2015
DOI: 10.1152/jn.00585.2014
|View full text |Cite
|
Sign up to set email alerts
|

Related neuropeptides use different balances of unitary mechanisms to modulate the cardiac neuromuscular system in the American lobster,Homarus americanus

Abstract: To produce flexible outputs, neural networks controlling rhythmic motor behaviors can be modulated at multiple levels, including the pattern generator itself, sensory feedback, and the response of the muscle to a given pattern of motor output. We examined the role of two related neuropeptides, GYSDRNYLRFamide (GYS) and SGRNFLRFamide (SGRN), in modulating the neurogenic lobster heartbeat, which is controlled by the cardiac ganglion (CG). When perfused though an isolated whole heart at low concentrations, both p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
26
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(28 citation statements)
references
References 82 publications
2
26
0
Order By: Relevance
“…The signals from the force transducers were amplified by a Model 44 Brownlee Precision Instrumentation amplifier and recorded with a Cambridge Electronic Design (CED) Micro 1401 digitizer paired with Spike2 version 7.03 software (CED, Cambridge, UK). The output of the force transducer is reported in grams rather than Newtons for consistency with other studies that have studied single locations on the length-tension curve (Fort et al, 2004(Fort et al, , 2007aStevens et al, 2009;Christie et al, 2010b;Dickinson et al, 2015).…”
Section: Whole-heart Preparationmentioning
confidence: 71%
See 4 more Smart Citations
“…The signals from the force transducers were amplified by a Model 44 Brownlee Precision Instrumentation amplifier and recorded with a Cambridge Electronic Design (CED) Micro 1401 digitizer paired with Spike2 version 7.03 software (CED, Cambridge, UK). The output of the force transducer is reported in grams rather than Newtons for consistency with other studies that have studied single locations on the length-tension curve (Fort et al, 2004(Fort et al, , 2007aStevens et al, 2009;Christie et al, 2010b;Dickinson et al, 2015).…”
Section: Whole-heart Preparationmentioning
confidence: 71%
“…The concentrations of SGRN (10 −9 mol l −1 ) and GYS (5×10 −10 mol l −1 ) were selected as the lowest concentrations that consistently produced a significant increase in contraction amplitude and frequency (Dickinson et al, 2015).…”
Section: Chemicalsmentioning
confidence: 99%
See 3 more Smart Citations