2009
DOI: 10.1016/j.amjcard.2009.01.294
|View full text |Cite
|
Sign up to set email alerts
|

Relation of Biomarkers and Cardiac Magnetic Resonance Imaging After Marathon Running

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

9
96
0
2

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 163 publications
(107 citation statements)
references
References 24 publications
9
96
0
2
Order By: Relevance
“…In contrast, several studies reported transient depression of RV systolic function and RV dilation after endurance sports without prognostic consequences (5,21,24 ). These transient changes may be due to exercise-induced pulmonary hypertension or volume load (21 ).…”
Section: Biomarker Changes After Strenuous Exercisementioning
confidence: 90%
See 1 more Smart Citation
“…In contrast, several studies reported transient depression of RV systolic function and RV dilation after endurance sports without prognostic consequences (5,21,24 ). These transient changes may be due to exercise-induced pulmonary hypertension or volume load (21 ).…”
Section: Biomarker Changes After Strenuous Exercisementioning
confidence: 90%
“…The exercise-induced increase in troponin could be due to release of cytoplasmic cTnT and cTnI, because exercise may increase membrane permeability of cardiomyocytes (19,20 ). This reversible membrane leakage might be due to increased mechanical stress on the cardiomyocytes, overload with free radicals, increased body temperature, or prolonged acidosis (19,21 ).…”
Section: Biomarker Changes After Strenuous Exercisementioning
confidence: 99%
“…The evidence that strenuous exercise can cause alterations in the metabolism and cardiovascular system are derived from several sporting events [2][3][4][5][6] . A meta-analysis of 26 studies demonstrated that troponin elevation occurs in approximately half of the participants of endurance tests, and this increase appears to be more common in shorter duration tests 7 .…”
Section: Introductionmentioning
confidence: 99%
“…The development of high sensitivity cardiac troponin assays has increased the analytical sensitivity with almost three orders of magnitude compared to the first generation assays, and has made it evident that cardiac troponins indeed are measurable in plasma also under normal conditions [12]. The previous belief that cardiac troponins are only released after irreversible myocardial damage is seriously challenged [13]. The vast majority of patients diagnosed with UA in the pre-troponin era have slight elevations of cardiac troponin, and using the most sensitive assays available it can be questioned whether 'true' UA does exist, i.e., without any evidence of myocardial damage ( = cardiac troponin elevation) [14,15].…”
Section: Diagnosismentioning
confidence: 99%