2022
DOI: 10.3174/ajnr.a7418
|View full text |Cite
|
Sign up to set email alerts
|

Relationship between 3D Morphologic Change and 2D and 3D Growth of Unruptured Intracranial Aneurysms

Abstract: BACKGROUND AND PURPOSE: Untreated unruptured intracranial aneurysms are usually followed radiologically to detect aneurysm growth, which is associated with increased rupture risk. The ideal aneurysm size cutoff for defining growth remains unclear and also whether change in morphology should be part of the definition. We investigated the relationship between change in aneurysm size and 3D quantified morphologic changes during follow-up. MATERIALS AND METHODS:We performed 3D morphology measurements of unruptured… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 22 publications
1
2
0
Order By: Relevance
“…This suggests that it is the topology of the aneurysm surface itself which is high indicative of growth or stability as opposed to UIA configuration relative to parent vessels. This result is also on par with previous studies, where measurements of just the UIA were used for distinguishing between growing and stable UIAs [34,150,154]. However, it is also worth noting that using a ROI as opposed to the UIA mesh does not greatly reduce the performance of the method.…”
Section: Discussionsupporting
confidence: 82%
See 1 more Smart Citation
“…This suggests that it is the topology of the aneurysm surface itself which is high indicative of growth or stability as opposed to UIA configuration relative to parent vessels. This result is also on par with previous studies, where measurements of just the UIA were used for distinguishing between growing and stable UIAs [34,150,154]. However, it is also worth noting that using a ROI as opposed to the UIA mesh does not greatly reduce the performance of the method.…”
Section: Discussionsupporting
confidence: 82%
“…As computer aided radiology tools continue to be developed, there is the possibility to measure UIAs in 3D, including their shape [147]. Quantitative shape/morphology measures of UIAs could be used, including to distinguish between growing and stable aneurysms [34,150,154]. Based on such morphological parameters, as well as classical parameters, UIA rupture risk prediction models have been developed [155,156].…”
Section: Introductionmentioning
confidence: 99%
“…3D morphological measurements were performed as described elsewhere. 14 Briefly, we annotated aneurysms by drawing a contour around the aneurysm on each axial slice, using in-house developed software implemented in MeVisLab (MeVis Medical Solutions). The software subsequently fitted a mesh around the aneurysm using a marching cubes algorithm.…”
Section: Methodsmentioning
confidence: 99%