2011
DOI: 10.1007/s10840-011-9623-8
|View full text |Cite
|
Sign up to set email alerts
|

Relationship between electroanatomical voltage mapping characteristics and breakout site of ventricular activation in idiopathic ventricular tachyarrhythmia originating from the right ventricular outflow tract septum

Abstract: The border area, including the LVA, tends to be the breakout site and/or origin of ventricular arrhythmias in idiopathic ventricular tachyarrhythmia originating from the RVOT septum.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
21
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(26 citation statements)
references
References 22 publications
5
21
0
Order By: Relevance
“…Therefore, the occurrence of these PPs and their association with His‐bundle activation time suggests that islets of residual cells (located within the fibrous trigone) that once originated from the conduction system and failed to regress during maturation might be actively involved in the genesis of VAs originating from this region. Similar findings have been described in several reports …”
Section: Discussionsupporting
confidence: 93%
“…Therefore, the occurrence of these PPs and their association with His‐bundle activation time suggests that islets of residual cells (located within the fibrous trigone) that once originated from the conduction system and failed to regress during maturation might be actively involved in the genesis of VAs originating from this region. Similar findings have been described in several reports …”
Section: Discussionsupporting
confidence: 93%
“…The mean number of points sampled in this study was 158 ± 34. In a similar study where 148 ± 27 points were sampled per patient, the SOO was identified at the border area (mean amplitude of 1.9 ± 0.3 mV) in 19 of the 28 patients …”
Section: Discussionmentioning
confidence: 85%
“…Second, a relatively small number of patients with low‐arrhythmia burden has been included for analysis. Third, abnormal local bipolar electrograms during sinus rhythm were defined as those displaying an amplitude of less than 1 mV, which is different from previous studies . However, we do believe that these thresholds are dependent on the electrode size and spacing.…”
Section: Study Limitationsmentioning
confidence: 89%
See 1 more Smart Citation
“…Pace mapping template matches over 92% performed using the Biosense Webster PaSo software was helpful in defining a successful ablation site in 13/17 VA ablated using pace mapping only. Other confirmatory findings at these sites included observing presystolic potentials, and induction of VT that had a similar QRS morphology to the spontaneous arrhythmia during RF energy delivery at these sites …”
Section: Discussionmentioning
confidence: 69%