Relationship between intracardiac impedance and left ventricular contractility in patients undergoing cardiac resynchronization therapy

Abstract: AimsCardiac resynchronization therapy (CRT) has dramatically improved the symptoms and prognosis of patients with heart failure in large randomized clinical trials. Optimization of device settings may maximize benefit on an individual basis, although the best method for this is not yet established. We evaluated the use of cardiogenic impedance measurements (derived from intracardiac impedance signals) in CRT device optimization, using invasive left ventricular (LV) dP/dtmax as the reference.Methods and results… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…Pacing leads bearing just standard electrodes can be used to assess cardiac impedance [21] . Different electrode arrangements are proposed for impedance assessment [17] , [21] [24] , namely the unipolar configuration (current is applied between the ventricular tip electrode and the device case and the corresponding voltage drop is measured at the same spots), the bipolar configuration (current is applied between two cardiac electrodes and the corresponding voltage drop is measured at the same spots), or different multipolar configurations (current is applied between two cardiac electrodes and the voltage drop is measured on another electrode pair). The transvalvular impedance (TVI) is a particular example of bipolar configuration, where the atrial pole is represented by the ring electrode placed in right atrium and the ventricular pole by either the tip or ring electrode of the right ventricular lead.…”
Section: Introductionmentioning
confidence: 99%
“…Pacing leads bearing just standard electrodes can be used to assess cardiac impedance [21] . Different electrode arrangements are proposed for impedance assessment [17] , [21] [24] , namely the unipolar configuration (current is applied between the ventricular tip electrode and the device case and the corresponding voltage drop is measured at the same spots), the bipolar configuration (current is applied between two cardiac electrodes and the corresponding voltage drop is measured at the same spots), or different multipolar configurations (current is applied between two cardiac electrodes and the voltage drop is measured on another electrode pair). The transvalvular impedance (TVI) is a particular example of bipolar configuration, where the atrial pole is represented by the ring electrode placed in right atrium and the ventricular pole by either the tip or ring electrode of the right ventricular lead.…”
Section: Introductionmentioning
confidence: 99%
“…Another invasive indicator, the peak rate of the LV pressure systolic increase over time, calculated as maximum dP/dt (dP/dt max ), is a simple indicator of cardiac contractility (14,21,28). Numerous studies have used dP/dt max with convincing results (9,20,22,32,35); however, this index is known to be preload dependent (23, 31), and it is also affected by the heart rate (HR) (8, 37). Both EF and dP/dt max thus have advantages and limitations, and they are often reported simultaneously in studies while it is not clear if they are complementary or redundant.…”
mentioning
confidence: 99%
“…Other companies like Biotronik (Berlin, Germany) and Medico (Milan, Italy), proposed impedance measurement as another way of assessing the ventricular contractility with an implanted device. [6][7][8][9] These methods are based on the assumption that the intracardiac impedance signals (cardiogenic impedances) depend on the blood volume contained in the cardiac chambers at any time, and that measuring of volumetric fluctuations within the heart during the cardiac cycle can be used to monitor cardiac contractility. The main limitation of this technique is that in some measurement configurations it reflects more the contractility of the right ventricle than of the left ventricle.…”
Section: Danko Tomasic Is An Employee and Shareholder Of Medtronic Inmentioning
confidence: 99%