2017
DOI: 10.1080/00207217.2017.1378380
|View full text |Cite
|
Sign up to set email alerts
|

Reliability analysis of component-level redundant topologies for solid-state fault current limiter

Abstract: Experience shows that semiconductor switches in power electronics systems are the most vulnerable components. One of the most common ways to solve this reliability challenge is componentlevel redundant design. There are four possible configurations for the redundant design in component-level. This paper presents a comparative reliability analysis between different componentlevel redundant designs for solid state fault current limiter (SSFCL). The aim of the proposed analysis is to determine the more reliable c… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 31 publications
0
5
0
Order By: Relevance
“…Capacitors are one the most fragile components in power electronic systems. [31][32][33] Therefore, the number of charging capacitors is another important point that should be compared for different topologies. To achieve the same voltage ratio, the proposed topologies in this paper and in Pan et al 26 have the same number of charging capacitors.…”
Section: Comparision Of the Proposed Converter With Other Similar Tmentioning
confidence: 99%
See 1 more Smart Citation
“…Capacitors are one the most fragile components in power electronic systems. [31][32][33] Therefore, the number of charging capacitors is another important point that should be compared for different topologies. To achieve the same voltage ratio, the proposed topologies in this paper and in Pan et al 26 have the same number of charging capacitors.…”
Section: Comparision Of the Proposed Converter With Other Similar Tmentioning
confidence: 99%
“…Capacitors are one the most fragile components in power electronic systems 31–33 . Therefore, the number of charging capacitors is another important point that should be compared for different topologies.…”
Section: Comparision Of the Proposed Converter With Other Similar Topmentioning
confidence: 99%
“…By using advanced control techniques [24]- [27], active thermal control systems can control losses and ensure that the device operates within a safe temperature range, which can prevent premature failure. Among these techniques, state of health monitoring is considered to be a cost-effective solution that strikes a balance between ensuring system reliability and cost-effectiveness [28]- [30]. The fundamental concept behind state of health monitoring involves monitoring changes in the values of different aging precursors in real-time or at start-ups.…”
mentioning
confidence: 99%
“…HE promotion of modern electric power system and their interconnections have led to the high fault currents levels that may go beyond of the maximum short-circuit ratings of the switchgears in some points of the grid. Despite advantages of modern networks, large power networks exhibit some problematic issues such as high complexity, lower security, and high-level fault currents [1], [2]. Furthermore, these power networks suffer from the probable decrease in the quality of the load voltage due to the nonlinear loads and high penetration of renewable energy systems.…”
mentioning
confidence: 99%
“…The superconductor based FCLs have a low or no power loss during normal and fault conditions, so they are attractive in industry [26]- [27]. However, in recent years due to the high technology demands and higher costs of the superconductive materials, application of non-superconductor FCLs is recommended [1], [9]. Apart from the great diversity of FCL's structures, an effective FCL should have the following characteristics:…”
mentioning