2015
DOI: 10.1097/aud.0000000000000089
|View full text |Cite
|
Sign up to set email alerts
|

Reliability and Clinical Test Performance of Cochlear Reflectance

Abstract: Objective Cochlear reflectance (CR) is the cochlear contribution to ear-canal reflectance. CR is equivalent to an otoacoustic emission (OAE) deconvolved by forward pressure in the ear-canal. Similar to other OAE measures, CR level is related to cochlear status. When measured using wideband noise stimuli, potential advantages of CR over other types of otoacoustic emissions include (1) the capability to cover a wider frequency range more efficiently by requiring fewer measurements, (2) minimal influence on the r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(14 citation statements)
references
References 47 publications
1
13
0
Order By: Relevance
“…This study extends our previous work on the relationship between CR and auditory status (Rasetshwane et al 2015). The main goals of this study were to (1) to compare the accuracy of CR and DPOAEs in terms of identification of auditory status (i.e., normal versus impaired), which we refer to as test performance and (2) to compare the accuracy of CR and DPOAEs in their prediction of audiometric thresholds.…”
Section: Introductionmentioning
confidence: 61%
See 3 more Smart Citations
“…This study extends our previous work on the relationship between CR and auditory status (Rasetshwane et al 2015). The main goals of this study were to (1) to compare the accuracy of CR and DPOAEs in terms of identification of auditory status (i.e., normal versus impaired), which we refer to as test performance and (2) to compare the accuracy of CR and DPOAEs in their prediction of audiometric thresholds.…”
Section: Introductionmentioning
confidence: 61%
“…The inclusion criteria for tympanometry (Otoflex 100, Madsen) required a peak-compensated static acoustic admittance between 0.3 and 2.5 mmhos and peak tympanometric pressure between −100 and +50 daPa. The upper limit of the admittance range is higher than typically used but was selected for consistency with previous studies in our laboratory (e.g., Rasetshwane et al 2015;Sieck et al 2016). The inclusion criterion for bone conduction (B71, Radioear) required air-bone gaps ≤ 10 dB.…”
Section: Participantsmentioning
confidence: 99%
See 2 more Smart Citations
“…The CR response datasets were combined into a single analysis rather than testing for replications, because of the relatively small sample size of the MUSC dataset (Figure 4) and identical protocols across sites. The same equipment and procedures were used because the Fultz et al (2020) experiment was implemented in collaboration with the coauthors at BTNRH (detailed in Fultz et al, 2020; Neely et al, 2019; Rasetshwane et al, 2015). The stimuli consisted of a wideband linear swept-frequency chirp at 60 dB SPL and WBN presented at 30, 40, and 50 dB SPL.…”
Section: Methodsmentioning
confidence: 99%