Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
ImportanceThe subjective experience of somatic symptoms is a key concern throughout the health care system. Valid and clinically useful instruments are needed.ObjectiveTo evaluate the measurement properties of 2 widespread patient-reported outcomes: the Patient Health Questionnaire–15 (PHQ-15) and Somatic Symptom Scale–8 (SSS-8).Data SourcesMedline, PsycINFO, and Web of Science were last searched February 1, 2024.Study SelectionEnglish-language studies reporting estimates pertaining to factor analysis, taxometric analysis, internal consistency, construct validity, mean scores in relevant groups, cutoffs, areas under the receiver operating characteristic curves (AUROCs), minimal clinically important difference, test-retest reliability, or sensitivity to change.Data Extraction and SynthesisSearch hits were reviewed by independent raters. Cronbach α, Pearson r, means, and between-group effect sizes indicative of sensitivity to change were pooled in random-effects meta-analysis. Study quality was assessed using 3 instruments. Reporting followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 reporting guideline.Main Outcomes and MeasuresComprehensive overview of evidence pertaining to the measurement properties of the PHQ-15 and SSS-8.ResultsA total of 305 studies with 361 243 participants were included. Most concerned routine care (178 studies) and the general population (27 studies). In factor analyses, both scales reflected a combination of domain-specific factors (cardiopulmonary, fatigue, gastrointestinal, pain) and a general symptom burden factor. The pooled PHQ-15 α was 0.81 (95% CI, 0.80-0.82), but with low item-total correlations for items concerning menstrual problems, fainting spells, and sexual problems (item-total correlations <0.40), and the SSS-8 α was 0.80 (0.77-0.83). Pooled correlations with other measures of somatic symptom burden were 0.71 (95% CI, 0.64-0.78) for the PHQ-15 and 0.82 (95% CI, 0.72-0.92) for the SSS-8. Reported AUROCs for identification of somatoform disorders ranged from 0.63 (95% CI, 0.50-0.76) to 0.79 (95% CI, 0.73-0.85) for the PHQ-15 and from 0.71 (95% CI, 0.66-0.77) to 0.73 (95% CI, 0.69-0.76) for the SSS-8. The minimal clinically important difference on both scales was 3 points. Test-retest reliability could not be pooled and was inconsistent for the PHQ-15 (PHQ-15: r = 0.65-0.93; ICC, 0.87; SSS-8: r = 0.996, ICC = 0.89). The PHQ-15 showed tentative sensitivity to change (g = 0.32; 95% CI, 0.08-0.56), but data for the SSS-8 were lacking.Conclusions and RelevanceIn this systematic review and meta-analysis, findings supported use of the PHQ-15 and SSS-8 for the assessment of symptom burden, but users should be aware of the complex, multifactorial structures of these scales. More evidence is needed concerning longitudinal measurement properties.
ImportanceThe subjective experience of somatic symptoms is a key concern throughout the health care system. Valid and clinically useful instruments are needed.ObjectiveTo evaluate the measurement properties of 2 widespread patient-reported outcomes: the Patient Health Questionnaire–15 (PHQ-15) and Somatic Symptom Scale–8 (SSS-8).Data SourcesMedline, PsycINFO, and Web of Science were last searched February 1, 2024.Study SelectionEnglish-language studies reporting estimates pertaining to factor analysis, taxometric analysis, internal consistency, construct validity, mean scores in relevant groups, cutoffs, areas under the receiver operating characteristic curves (AUROCs), minimal clinically important difference, test-retest reliability, or sensitivity to change.Data Extraction and SynthesisSearch hits were reviewed by independent raters. Cronbach α, Pearson r, means, and between-group effect sizes indicative of sensitivity to change were pooled in random-effects meta-analysis. Study quality was assessed using 3 instruments. Reporting followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 reporting guideline.Main Outcomes and MeasuresComprehensive overview of evidence pertaining to the measurement properties of the PHQ-15 and SSS-8.ResultsA total of 305 studies with 361 243 participants were included. Most concerned routine care (178 studies) and the general population (27 studies). In factor analyses, both scales reflected a combination of domain-specific factors (cardiopulmonary, fatigue, gastrointestinal, pain) and a general symptom burden factor. The pooled PHQ-15 α was 0.81 (95% CI, 0.80-0.82), but with low item-total correlations for items concerning menstrual problems, fainting spells, and sexual problems (item-total correlations <0.40), and the SSS-8 α was 0.80 (0.77-0.83). Pooled correlations with other measures of somatic symptom burden were 0.71 (95% CI, 0.64-0.78) for the PHQ-15 and 0.82 (95% CI, 0.72-0.92) for the SSS-8. Reported AUROCs for identification of somatoform disorders ranged from 0.63 (95% CI, 0.50-0.76) to 0.79 (95% CI, 0.73-0.85) for the PHQ-15 and from 0.71 (95% CI, 0.66-0.77) to 0.73 (95% CI, 0.69-0.76) for the SSS-8. The minimal clinically important difference on both scales was 3 points. Test-retest reliability could not be pooled and was inconsistent for the PHQ-15 (PHQ-15: r = 0.65-0.93; ICC, 0.87; SSS-8: r = 0.996, ICC = 0.89). The PHQ-15 showed tentative sensitivity to change (g = 0.32; 95% CI, 0.08-0.56), but data for the SSS-8 were lacking.Conclusions and RelevanceIn this systematic review and meta-analysis, findings supported use of the PHQ-15 and SSS-8 for the assessment of symptom burden, but users should be aware of the complex, multifactorial structures of these scales. More evidence is needed concerning longitudinal measurement properties.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.