2019
DOI: 10.1109/tcpmt.2019.2919866
|View full text |Cite
|
Sign up to set email alerts
|

Reliability Challenges in Fabrication of Flexible Hybrid Electronics for Human Performance Monitors: A System-Level Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 28 publications
0
18
0
Order By: Relevance
“…In test setups similar to those of Soman et al [ 102 ] and Hamasha et al [ 22 ], both static and dynamic bending tests of flexible electronics can be performed.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In test setups similar to those of Soman et al [ 102 ] and Hamasha et al [ 22 ], both static and dynamic bending tests of flexible electronics can be performed.…”
Section: Discussionmentioning
confidence: 99%
“…Soman et al [ 102 ] report on an environmental flexure tester, Associated Environmental Systems (Model No. BHK 4108), to investigate their samples using a flexure test ( Figure 15 ).…”
Section: Bending Machinesmentioning
confidence: 99%
See 1 more Smart Citation
“…12 Its reduced adhesivity, due to the low-surface energy and hydrophobic nature limits mechanical durability and electrical conductivity by cracking and peeling of the conducting electrodes. 13,14 The stretchable electrodes are fabricated by two conceptually different but complementary strategies to prevent mechanical failure. The first strategy designs geometries of conductive materials into various structures, such as serpentine interconnects, 15 three-dimension coiled structures, 16,17 nano meshes, 18,19 and "wavy" structures, 20,21 a thin gold film of wavy silicon (Si) nanoribbons or a spring-like metal trace pattern, [22][23][24][25][26] and then attach them to stretchable substrates.…”
Section: Introductionmentioning
confidence: 99%
“…However, it is found toxic after oral application, even in small quantities and the low‐molecular weight linear PDMS can affect central nervous system with mild stupefaction 12 . Its reduced adhesivity, due to the low‐surface energy and hydrophobic nature limits mechanical durability and electrical conductivity by cracking and peeling of the conducting electrodes 13,14 . The stretchable electrodes are fabricated by two conceptually different but complementary strategies to prevent mechanical failure.…”
Section: Introductionmentioning
confidence: 99%