2021
DOI: 10.1016/j.ultrasmedbio.2021.04.028
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of Processing 3-D Freehand Ultrasound Data to Define Muscle Volume and Echo-intensity in Pediatric Lower Limb Muscles with Typical Development or with Spasticity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
45
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 18 publications
(49 citation statements)
references
References 46 publications
(91 reference statements)
2
45
2
Order By: Relevance
“…Third, images were obtained close to the tendinous inscription and not at different locations within each compartment; however, as the anatomical cross-sectional area of ST varies greatly along its length ( 47 ), confining data acquisition to a small region of the whole muscle reduced the effects anatomical cross-sectional area may have on the slope of the increase in the shear modulus-force relationship ( 22 ). In addition, image quality can be poor in more proximal portions of ST prox ( 18 , 20 ). Fourth, although we ensured electromyography silence of semimembranosus during data acquisition, we cannot definitively confirm ST was inactive as it was not possible to simultaneously acquire electromyograms and elastograms given 1 ) the large gluteals covering ST prox proximal to the transducer, and 2 ) the available ST dist electrode position being in the distal portion of the muscle, where ST is small compared with the adjacent synergists ( 47 ) and thus exposing the recordings to high amounts of cross talk.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Third, images were obtained close to the tendinous inscription and not at different locations within each compartment; however, as the anatomical cross-sectional area of ST varies greatly along its length ( 47 ), confining data acquisition to a small region of the whole muscle reduced the effects anatomical cross-sectional area may have on the slope of the increase in the shear modulus-force relationship ( 22 ). In addition, image quality can be poor in more proximal portions of ST prox ( 18 , 20 ). Fourth, although we ensured electromyography silence of semimembranosus during data acquisition, we cannot definitively confirm ST was inactive as it was not possible to simultaneously acquire electromyograms and elastograms given 1 ) the large gluteals covering ST prox proximal to the transducer, and 2 ) the available ST dist electrode position being in the distal portion of the muscle, where ST is small compared with the adjacent synergists ( 47 ) and thus exposing the recordings to high amounts of cross talk.…”
Section: Discussionmentioning
confidence: 99%
“…For example, the maximum single fiber and fiber bundle tangent moduli are ∼20–25 times greater in the frog compared with human ST muscle ( 13 , 14 ). Furthermore, it has been established that neuromuscular properties and behavior observed in cats do not always extend to humans ( 15 , 16 ) and thus observations made from cat ST must be empirically confirmed in human ST. Studies clearly distinguishing human ST prox and ST dist have been limited to measuring intramuscular electromyographic amplitudes during isometric contractions ( 17 ) and architectural and morphological measures from cadavers ( 1 , 8 , 18 ) or children with and without spasticity ( 19 , 20 ). As none of these previous studies directly quantified forces or stiffness within each compartment, further information is required to adequately assess the mechanical properties of human ST compartments.…”
Section: Introductionmentioning
confidence: 99%
“…Both data collection and processing were performed using STRADWIN software (version 6.0; Mechanical Engineering, Cambridge University, Cambridge, UK) for four lower limb muscles: m. rectus femoris (RF), m. semitendinosus (ST), m. tibialis anterior (TA), and m. gastrocnemius medialis (MG). The reliability of 3DfUS has been confirmed for the plantar flexor muscles (50-52), as well as for the processing of the TA, RF, and ST (53). MV (in milliliters) was estimated by drawing equally spaced transverse plane segmentations along the inside of the muscle border for ∼5% of all acquired images, followed by an automatic linear interpolation.…”
Section: Three-dimensional Freehand Ultrasonographymentioning
confidence: 92%
“…Large amounts of acoustic transmission gel were used and combined with the Portico (i.e., custom-shaped plastic mount combined with gel pad) which minimizes muscle deformation during ultrasound acquisitions [56]. The acquired images of the automatically generated 3D muscle reconstruction were manually analyzed by a single experienced researcher [57]. Prior to the statistical analysis, this processor was blinded for the patient sensitive data, the timing of assessment and the group allocation.…”
Section: Assessmentmentioning
confidence: 99%