2018
DOI: 10.1016/j.elspec.2017.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Reliable absorbance measurement of liquid samples in soft X-ray absorption spectroscopy in transmission mode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
32
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 38 publications
(32 citation statements)
references
References 44 publications
0
32
0
Order By: Relevance
“…9,[11][12][13] Recently, we have successfully developed a transmission-type liquid flow cell for XAS of liquid samples in transmission mode, where the liquid layer is sandwiched between two 100 nm thick Si3N4 (or SiC) membranes and the liquid thickness is controllable from 20 to 2000 nm. 4,22,23 In this section, we discuss the details of the XAS measurement system and how to control the liquid thickness for obtaining the appropriate absorbance in XAS spectra. Figure 1 shows an XAS measurement system for liquid samples, 4,22,23 which is settled in the soft X-ray beamline BL3U at UVSOR-III Synchrotron.…”
Section: Xas Of Liquid In Transmission Modementioning
confidence: 99%
“…9,[11][12][13] Recently, we have successfully developed a transmission-type liquid flow cell for XAS of liquid samples in transmission mode, where the liquid layer is sandwiched between two 100 nm thick Si3N4 (or SiC) membranes and the liquid thickness is controllable from 20 to 2000 nm. 4,22,23 In this section, we discuss the details of the XAS measurement system and how to control the liquid thickness for obtaining the appropriate absorbance in XAS spectra. Figure 1 shows an XAS measurement system for liquid samples, 4,22,23 which is settled in the soft X-ray beamline BL3U at UVSOR-III Synchrotron.…”
Section: Xas Of Liquid In Transmission Modementioning
confidence: 99%
“…The relative intensities between main-edge and post-edge of liquid water and crystalline ice Ih are substantially different. 6,[8][9][10][11][20][21][22][23][24] As one of the most qualitative differences, the intensity of main-edge is higher than that of the post-edge in the XAS of liquid water, while the opposite trend is true for the spectra in the ice.…”
Section: Introductionmentioning
confidence: 99%
“…11,18,[20][21][22] Experimentally, the pre-edge feature is present in both liquid water and ice but is more intense in the former. The relative intensities between main-edge and post-edge of liquid water and crystalline ice Ih are substantially different.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, high-resolution X-ray absorption spectroscopy (XAS), has emerged to be a powerful experimental technique to probe the water structure at molecular scale [13][14][15][16][17][18][19]. Allowed by Franck-Condon principle [20], the electrons leaving the oxygen core can be described as excited electronic states from an instantaneously frozen snapshot of water at equilibrium.…”
mentioning
confidence: 99%